4.4 Installation of the CO Line & Extension Board
BOARD
LINE
CONNECTOR
TYPE
DESCRIPTION
CABLE
REMARK
CHB308
3 CO and 8SLT or 8 DKT
RJ11
3 CO Line and 8
Hybrid Interface
DKT : 4 wire
CO,SLT:2wire
CSB316
3 CO and 16 SLT
RJ11
3 CO Line and 16 SLT
Interface
2 wire
SLIB8
8 SLT
RJ11
8 SLT Interface
2 wire
VOIB
4 channels
RJ45
Voice over IP unit
4 channels
PRHB8
1 PRI and 8SLT or 8 DKT
RJ45, RJ11
PRI and 8 Hybrid
interface
PRI : 8 wire
DKT : 4 wire
SLT : 2 wire
4.4.1 CHB308 (3 CO Line and 8 Hybrid Interface Board)
The CHB308 can be installed on the CHB308/CSB316/SLIB8 (CN2) connector of the MBU or EMBU, and provides 3
CO/PBX Loop Start CO Line interfaces that support Pulse/DTMF signaling. Each interface contains ring and loop
current circuits, A/D and D/A conversions, and pulse signaling circuitry.
It also provides 8 Hybrid (8 DKTs or 8 SLT interfaces) ports, and can detect FSK signal for incoming Caller ID, DTMF
signal for incoming caller ID, call progress tone. It also provides three on-hook connection paths for CID/SMS.
FIGURE 4.4.1 CHB308