C
OMPLIANCES
– 4 –
ES-2010G / ES-2010GP
for electrical equipment used within certain voltage limits and the
Amendment Directive 93/68/EEC. For the evaluation of the compliance
with these Directives, the following standards were applied:
P
OWER
C
ORD
S
AFETY
Please read the following safety information carefully before installing the
switch:
WARNING: Installation and removal of the unit must be carried out by
qualified personnel only.
The following declaration is for both the ES-2010G and the ES-2010GP
model:
RFI Emission:
◆
Limited class A according to: EN 55022:2006+A1:
2007
◆
Limited class A for harmonic current emission
according to EN 61000-3-2/2006
◆
Limitation of voltage fluctuation and flicker in low-
voltage supply system according to EN 61000-3-
3:2008
Immunity:
◆
Product family standard according to EN 55024:
1998+A2:2003
◆
Electrostatic Discharge according to IEC 61000-4-
2:2008 (Contact Discharge: ±4 kV, Air discharge:
±8 kV)
◆
Radio-frequency electromagnetic field according to
IEC 61000-4-3:2006+A1:2007+A2:2010 (80 –
1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)
◆
Electrical fast transient/burst according to IEC
61000-4-4:2004
(AC/DC power supply: ±1 kV, Data/Signal lines: ±5
kV)
◆
Surge immunity test according to IEC 61000-4-
5:2005
(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2
kV)
◆
Immunity to conducted disturbances, Induced by
radio-frequency field: IEC 61000-4-6:2008
(0.15 – 80 MHz with 1 kHz AM 80% Modulation: 3 V/
m)
◆
Power frequency magnetic field immunity (1 A/m at
frequency 50 Hz) IEC 61000-4-8:2009
◆
Voltage dips, short interruptions and voltage
variations immunity test according to IEC 61000-4-
11:2004
(>95% Reduction @10 ms, 30% Reduction @500
ms, >95% Reduction @5000 ms)
LVD:
◆
EN 60950-1:2006+A11:2009