Alerts by Status Indicators
1.6
State of charge
1.6.1
Too low SOC
Indicators
Alert Level Alert condition
Charge
limit
Discharge
limit
Release condition
Warning
< 2.0% for 10 s
100%
50% > 3.0% for 10 s
The SOC is lower than the tolerance limit.
1. Check the blue indicators to see the SOC.
2. Manipulate the higher level system to charge the ESS with a current less than or
equal to 63 A until the SOC is higher than or equal to 3%.
1.6.2
Too high SOC
Indicators
Alert Level Alert condition
Charge
limit
Discharge
limit
Release condition
Warning
> 99.0% for 10 s
50%
100% < 98.0% for 10 s
The SOC is higher than the tolerance limit.
1. Check the blue indicators to see the SOC.
2. Manipulate the higher level system to discharge the ESS with a current less than
or equal to 63 A until the SOC is lower than or equal to 98%.
12