Cautions:
The effect should be installed outside areas where persons may reach it, walk by or be seated.
CAUTION
When installing the device, make sure there is no highly
inflammable material within a distance of min. 0,5m
Overhead mounting requires extensive experience, including amongst others calculating
working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the
installation yourself. Improper installation can result in bodily injury.
CAUTION
The electric connection must only be carried out by a qualified electrician.
Before mounting make sure that the installation area can hold a minimum point load of 10 times the
device’s weight.
Connect the fixture to the mains with the power plug.
installation via the Omega holders
Screw one clamp each via a M10 screw and nut directly into the bracket of the scanner. Pull the safety-chain
through the bracket of the base and over the trussing system or a safe fixation spot.
- 7 - WIT044 V1.6-03NR