background image

simultaneously. 
If you set a different address, each unit will start to “listen” to the channel number you have set, 
based on the quantity of control channels of the unit. That means changing the settings of one 
channel will affect only the selected fixture. 
 
In the case of the spot head, which is a 11 channel fixture, you should set the starting address of the   
first unit to 1, the second unit to

 

9 (8 + 1), the third to 17 (9 + 8), and so on.

 

 
Note:

 

The odes

wn via the

 m

 of DMX 512 data and lamp are sho

 display: 

. .

.

.

Lamp on

Lamp on

DMX OK

DMX OK

NO DMX

NO DMX

Lamp off

Lamp off

 

 
1. After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data is 
received, the the display will show 

"A.001"

 with the actually set address. If there is no data received at the 

DMX-input, the display will flash 

"A001"

 with the actually set address. 

This situation can occur if: 
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device. 
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap in the 
input connector. 
 
It’s necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to ensure 
proper transmission on the DMX data link. 
 
2. If the lamp is on, the the display will show 

"A00.1"

 with the actually set address. If the lamp is off, the the 

display will show 

"A001"

 with the actually set address. 

 
Control Board 

The Control Board offers several features: you can simply set the starting address, switch on and off the lamp, run 
the pre-programmed program or make a reset. 
The main menu is accessed by pressing the Mode/esc-button until the display starts flashing. Browse through the 
menu by pressing the Up-button or Down-button. Press the Enter-button in order to select the desired menu. You 
can change the selection by pressing the Up-button or Down-button. Confirm every selection by pressing the 
Enter-button. You can leave every mode by pressing the Mode/esc-button . The functions provided are described in 
the following sections. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                          - 9 -                                WIT044  V1.6-03NR 

Summary of Contents for BARREL 250

Page 1: ...USER S MANUAL SCANNER www lfxgroup com BARREL 250 KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...t movement tilt 45 3 operation mode DMX controlled stand alone or sound activated via built in microphone 9 colors plus white with two direction rainbow effect Switchable colour change mode 1 only ful...

Page 3: ...t on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class I Therefore it is essenti...

Page 4: ...device While choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust The minimum distance between light output from the projector and the illumi...

Page 5: ...ratures than which the device was designed for For the installation you need one CDMT150 G12 lamp MSD250 2 GY9 5 lamp Procedure 1 2 3 4 1 Unscrew the 2 screws on the back of the housing holding the pl...

Page 6: ...onstructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate safety...

Page 7: ...ice If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury CAUTION The electric connection must only be carried out by a qualified...

Page 8: ...s then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below Address 1 Address 9 Address 17 Projector DMX start address selection All fixtures should be gi...

Page 9: ...nnected with the input of the device the controller is switched off or defective if the cable or connector is defective or the signal wires are swap in the input connector It s necessary to insert the...

Page 10: ...ON OFF Tilt Reverse REST Reset LODA ON OFF Restore factory settings 1 SET VER V 1 0 V 9 9 Software version LADJ ON OFF Lamp adjustment 2 ADJU TEST T 01 T 30 Test function of each channel MATI 0000 999...

Page 11: ...wish to enable this function or press DOWN to select OFF if you don t 4 Press ENTER to confirm or press MODE ESC to return to main menu Program Run Master setting With the function RUN you can run the...

Page 12: ...MODE ESC to return to the main menu Shut off LED display With this function you can shut off the LED display after 2 minutes 1 Select CLDI by pressing UP or DOWN button 2 Press ENTER the display show...

Page 13: ...2 Press ENTER the display shows V X X X X stands for the version number e g V 1 0 V 2 6 3 Press MODE ESC to return to the main menu Main menu 3 1 Press MODE ESC to enter the main menu display flashing...

Page 14: ...h to enable this function or press DOWN button to OFF if you don t 4 Press ENTER to confirm or Press MODE ESC to return to the main menu Clear lamp time With this function you can clear the running ti...

Page 15: ...d the display shows ssing UP or DOWN button iting the display will change to the next scene 3 14 to edit and other scenes you can edit and save a maximum of 48 scenes enes can be called Editing via th...

Page 16: ...97 Rot gobo 6 metal 98 115 Rot gobo 7 metal 116 135 Rot gobo 1 metal s 136 155 Rot gobo 2 metal shake 156 175 Rot gobo 3 metal shake 176 195 Rot gobo 4 metal shake 196 215 Rot gobo 5 metal shake 216 2...

Page 17: ...unction Ch l 8 0 19 colour change normal 20 39 colour change to any po 40 59 No function 60 79 No function 80 99 Motor reset 00 119 Internal prog 120 139 Internal program 2 140 159 Internal program 3...

Page 18: ...28 140 colour change to any position 141 153 Motor reset 154 166 Internal prog 167 179 Internal program 2 180 192 Internal program 3 193 205 Internal program 4 206 218 Internal program 5 219 231 Inter...

Page 19: ...re starting maintenance operation e recommend a frequent cleaning of the device Please use a moist lint free cloth Never use ble parts inside the device except for the lamp Please refer to the genuine...

Page 20: ...NITER THERMOSTAT FUSE CAP TRANSFORMER POWER AC10V AC20V FAN GOBO MOTOR GOBO RO MOTOR COLOR MOTOR TILT MOTOR PAN MOTOR STROBE MOTOR B LP N SCAN7CH B01B SCAN7CH 05 MINI CONTROL 04B Color magnetic sensor...