23
300267596_002_C0 - 11/2016 - © Leybold
5.3 Leybold Service
Whenever you send us in equipment, indicate whether the equipment is
contaminated or is free of substances which could pose a health hazard. If
it is contaminated, specify exactly which substances are involved. You must
use the form we have prepared for this purpose.
A copy of the form has been reproduced at the end of these Operating
Instructions: “Declaration of Contamination for Compressors, Vacuum Pumps
and Components”. Another suitable form is available from www.leybold.com
→
Documentation
→
Download Documents.
Attach the form to the equipment or enclose it with the equipment.
This statement detailing the type of contamination is required to satisfy legal
requirements and for the protection of our employees.
We must return to the sender any equipment which is not accompanied by a
contamination statement.
The pump must be packaged in such a way that it will not be damaged
during shipping, and so that no harmful substances can escape from the
package.
When disposing of used oil, please observe the relevant environmental
regulations.
5.4 Maintenance Work
Checking the oil
A. Oil level
The pump’s oil level during operation must always be between the middle
and top edge of the oil-level glass.
When necessary, switch off the pump and add the correct quantity of oil.
High oil consumption often indicates that exhaust filters are clogged.
The oil level should be checked at least once a day.
B. Oil Change, Replacing the Oil Filter (if installed)
Tool required:
■
oil filter key (Ref. No. 710 73 532)
Always change the oil when the pump is switched off but still at working
temperature.
If there is a risk of the oil being polymerized by the connected process,
change the oil immediately after operation of the pump.
Pump when operating is hot and some surfaces could reach a temperature
higher than 80 °C (176 °F).
There is a risk of burn by touching. Take note of the warning labels on the
pump.
Caution
Warning
Formulaire
Contamination
Maintenance