Installation
65
300314330_002_C7 - 05/2021 - © Leybold
RUVAC
4400/7000
RUVAC
2001
RUVAC
2500
RUVAC
700
Fig. 3.23 Roots pump adapters
3.8 Mounting Accessories
3.8.1 Roots Pump Adapter
The adapters serve as a connecting component when fitting a Roots vacuum
pump onto the DRYVAC.
The adapter mounting is described in the corresponding Operating
Instructions.
After fitting, we recommend running of a leak search.
The eye-bolts at the RUVAC must
not
be used to lift the pump combina-
tion.
When transporting, the DRVAC and the RUVAC need to be separated for
safety reasons and reassembled at the new destination.
Exception: The WH 2500 can be lifted at its 4 eye-bolts together with the
DRYVAC if no other accessories are fitted.
CAUTION