SV Neo D 16 – 25 - 40 – 65
Jan. 2018
32 / 51
3.4 Start-up
Control Parameters for the Ignition Prevention System
Temperature
switch
Temperature
Sensor PT100
Oil Casing
Pressure
Switch
Oil Level
Switch
Alarm Value
N/A
95 °C
N/A
N/A
Pump Stop
Value and
Timer
105 °C
At switching
Immediately
105 °C
Immediately
At switching
After 20 s
At switching
After 20 s
Caution
The oil for the first filling is supplied with the pump. Before switching on, always
make sure that the pump contains enough oil. The normal oil level in a still
standing pump is in the upper half of the sight glass. If oil has to be added,
unscrew the oil-fill plug, add oil and screw the plug firmly back in.
The SOGEVAC
®
is designed for normal start-up at temperatures over 12°C
(54°F) (as per PNEUROP).
Caution
Before starting the pump ensure that the attached accessories meet the
requirements of your application and that safe operation is ensured.
Never expose part of the body to the vacuum. Do not lay the hand on the
intake to check suction. Exposure of a part of the body to the vacuum result in
a rush of blood in the exposed part.
There is a danger of injury. Never operate the pump with an open and thus
accessible inlet.
Vacuum connections as well as oil filling and oil draining openings must not be
opened during operation of the pump.
The safety regulations which apply to the specific application in each case
must be observed. This applies in particular to installation, operation and
maintenance (servicing) as well as waste disposal and transportation.
Warning
Installation
Summary of Contents for 970100V
Page 12: ...SV Neo D 16 25 40 65 Jan 2018 12 51 Dimensional drawing NEO D 16 Fig 1 1 Description...
Page 13: ...SV Neo D 16 25 40 65 Jan 2018 13 51 Dimensional drawing NEO D 25 Fig 1 2 Description...
Page 14: ...SV Neo D 16 25 40 65 Jan 2018 14 51 Installation drawing NEO D 25 Fig 1 2 Description...
Page 15: ...SV Neo D 16 25 40 65 Jan 2018 15 51 Dimensional drawing NEO D 40 Fig 1 3 Description...
Page 16: ...SV Neo D 16 25 40 65 Jan 2018 16 51 Dimensional drawing NEO D 65 Fig 1 4 Description...
Page 44: ...SV Neo D 16 25 40 65 Jan 2018 44 51 6 Trouble shooting Trouble shooting...
Page 47: ...SV Neo D 16 25 40 65 Jan 2018 47 51 Spare parts...
Page 48: ...SV Neo D 16 25 40 65 Jan 2018 48 51 CE Declaration CE Declaration...
Page 49: ...SV Neo D 16 25 40 65 Jan 2018 49 51 Declaration of Contamination...
Page 50: ...SV Neo D 16 25 40 65 Jan 2018 50 51 Notes Notes...