2.2 Mounting orientation
See required space on drawings in paragraph 1.2.
Pumps which have been filled with oil must only be moved in the upright
position (horizontally). Otherwise oil may escape. The angle of slope may not
be over 10° max. Avoid any other orientations while moving the pump. Check
the pump for the presence of any oil leaks, because there is the danger that
someone may slip on the oil which has leaked from the pump. Only use the
lifting lugs which are provided on the pump to lift the pump with the specified
lifting devices.
Make sure that these have been installed safety. Use suitable lifting
equipment. Make sure that all safety regulations are observed. Use only lifting
devices appropriated to the pump weight. Check name plate. Do not use
other pump elements than the lifting lugs as handles.
Caution
2.3 Storage
Before stocking the pump for a long time put it back in its original condition
(blank off inlet and exhaust ports with the shipping seals, drain the oil) and
store the pump in a dry place at room temperature.
Storage temperature: - 15°C to + 50°C
Until the pump is put back in to service again, the pump should be stored in a
dry place, preferably at room temperature (20 °C - 168 °F). Before taking the
pump out of service, it should be properly disconnected from the vacuum
system, purged with dry nitrogen and the oil should be exchange too. The
inlet and exhaust ports of the pump must be blanked off using the shipping
seals which are included upon delivery of the pump.
The gas ballast must be closed and if the pump is to be shelved for a longer
period of time is should be sealed in a plastic bag together with a desiccant
(Silicagel).
If the pump has been shelved for over one year, standard maintenance must
be done and the oil must be exchanged too before the pump is put in to
service once more.
We recommend that you contact the service from Leybold.
Caution
Transport and Storing
Summary of Contents for 970100V
Page 12: ...SV Neo D 16 25 40 65 Jan 2018 12 51 Dimensional drawing NEO D 16 Fig 1 1 Description...
Page 13: ...SV Neo D 16 25 40 65 Jan 2018 13 51 Dimensional drawing NEO D 25 Fig 1 2 Description...
Page 14: ...SV Neo D 16 25 40 65 Jan 2018 14 51 Installation drawing NEO D 25 Fig 1 2 Description...
Page 15: ...SV Neo D 16 25 40 65 Jan 2018 15 51 Dimensional drawing NEO D 40 Fig 1 3 Description...
Page 16: ...SV Neo D 16 25 40 65 Jan 2018 16 51 Dimensional drawing NEO D 65 Fig 1 4 Description...
Page 44: ...SV Neo D 16 25 40 65 Jan 2018 44 51 6 Trouble shooting Trouble shooting...
Page 47: ...SV Neo D 16 25 40 65 Jan 2018 47 51 Spare parts...
Page 48: ...SV Neo D 16 25 40 65 Jan 2018 48 51 CE Declaration CE Declaration...
Page 49: ...SV Neo D 16 25 40 65 Jan 2018 49 51 Declaration of Contamination...
Page 50: ...SV Neo D 16 25 40 65 Jan 2018 50 51 Notes Notes...