2. 

Safety 

2.1 

General Information 

The GRAPHIX is supplied ready for immediate operation. These Operating Instructions shall 
assist you during commissioning of the instrument. For further informations please refer to 
the detailed Operating Instructions on the supplied USB stick. 
 

2.2 

Key to Symbols 

Important  instructions  relating  to  technical  safety  and  safe  operation  are  emphasised  by 
symbols. 

 

 

DANGER or WARNING:

 

Information designed to prevent any kind of injury to persons. 

 

 

DANGER:  

Information designed to prevent injury to persons and damage to equipment 
in connection with electricity. 

 



 

NOTICE:  

General information pointing to further information, respectively reference 
sections.

 

 

2.3 

Basic Safety Information 

  During  all  work  like  installation,  maintenance  and  repair  activities,  comply  with  the 

pertinent safety regulations. 

 

 

DANGER: Mains Voltage 

Coming  into  contact  with  components  at  mains  voltage  level  within  the 
instrument can be dangerous to life when inserting objects or allowing liquids 
to enter the instrument  
 

 

 

WARNING: Improper Utilisation 

Improper utilisation of the instrument can damage it. For this reason operate, 
respectively  use  the  instrument  only  in  agreement  with  the  manufacturer

’s 

specifications.  

 

 

WARNING: Wrong Connection and Operating Data. 

Wrong  connection  and  operating  data  can  damage  the  instrument.  Comply 
with all specified connection and operating data. 

 
 
 
 
 
 
 
 

Summary of Contents for 230680V01

Page 1: ...Catalog No 230680V01 230681V01 230682V01 GRAPHIXONE GRAPHIXTWO GRAPHIXTHREE Vacuum Gauge Controller Operation Manual GA300553102_002_C2...

Page 2: ......

Page 3: ...Symbols 10 4 4 1 Symbols for the Controls 10 4 4 2 Symbols for the Language Selection 11 4 4 3 Status and Warning Symbols 11 4 5 Measuring Mode 12 5 Maintenance and Service 13 5 1 Maintenance 13 5 2 C...

Page 4: ...HIX controller is a display and operating unit with a graphic user interface for sensors with an analogue or digital interface of the company Leybold GmbH or from other manufacturers Depending on the...

Page 5: ...sume any responsibility or warranty in case the operator or third persons do not observe the information given in this document do not use the product as intended modify the product in any way convers...

Page 6: ...h electricity NOTICE General information pointing to further information respectively reference sections 2 3 Basic Safety Information During all work like installation maintenance and repair activitie...

Page 7: ...measurement channel 2 for GRAPHIX TWO and THREE only for sensors CH2 A and CH2 B E1 E2 Connection of measurement channel 3 for GRAPHIX THREE only for sensors CH3 A and CH3 B F Relay output connection...

Page 8: ...sible You may select between the following display modes Normal Default display mode which provides all important information on the connected sensors Chart Graphic display of the pressure history of...

Page 9: ...e functions In this way you may configure your GRAPHIX controller and also utilise further functions offered by the instrument Channel Menu Buttons Briefly touching the desired channel invokes the cha...

Page 10: ...Enabling display mode Leak Test Speedo Channel 1 Enabling display mode Speedo for channel 1 Speedo Channel 2 Enabling display mode Speedo for channel 2 Speedo Channel 3 Enabling display mode Speedo f...

Page 11: ...ge RU Russian Polish Select menu language PL Polish Turkish Select menu language TR Turkish Table 4 Symbols for language selection 4 4 3 Status and Warning Symbols Symbol Designation Explanation Statu...

Page 12: ...in specified measuring range Measuring value and additional warning symbol in the display mode Normal and Speedo or Measuring value displayed by a yellow font in the display modes Chart Big and Leak...

Page 13: ...n the USB stick in the folder RECOVERY o After the reset process has been completed the instrument will automatically restart with the default parameters o The GRAPHIX controller will now be ready for...

Page 14: ...Setup o The question Are you sure is displayed to ensure that you really want to run the reset When not wanting to run the reset tap the button to cancel the reset process o The main menu is then disp...

Page 15: ...yed again To run the update tap the button Start update o On the memory at the USB interface is installed the folder RECOVERY o Configuration data are stored in a file with the format rescue txt on th...

Page 16: ...measurement channel Acknowledge this message by selecting and terminating the channel menu at the corresponding channel Analog sensor signal out of range too high Error H 1 4 The measurement signal f...

Page 17: ...memory stick Error usb file closing none 3 File on USB stick cannot be stored Check the attached USB memory stick Error usb write none 4 USB stick not recordably Check the attached USB memory stick Er...

Page 18: ...n The setup value is saved To exit tap the button o The parameter selection display is displayed again 6 3 Help in Case of Malfunctions If the malfunction persists even after having exchanged the sens...

Page 19: ...ry room During storage the following ambient conditions need to be maintained Ambient temperature 20 60 C Humidity of the air As low as possible Preferably in a sealed plastic bag with desiccant 7 3 W...

Page 20: ...rvice zh leybold com Spain Leybold Spain S A C Huelva 7 E 08940 Cornell de Llobregat Barcelona Sales T 34 93 666 43 11 F 34 93 666 43 70 sales ba leybold com Service T 34 93 666 46 11 F 34 93 685 43 7...

Reviews: