Maintenance
4.1
Table - Maintenance
When the maintenance interval has been reached, contact Leybold to
arrange the required maintenance. Never disassemble, reassemble or alter
the pump yourself. We are not responsible for any accidents caused by
disassembly, assembly or alteration which was done by the user or non
specialist.
Maintenance interval
Where to inspect
Yearly or every
8.000 hr
Biennially or every
16.000 hr
every 400 times
vapor pumping
Remarks
Needle bearing - FS (2)
grease /
▲
●
▲
Needle bearing - OS
grease /
▲
●
▲
Ball bearing - FS (1)
▲
●
▲
Needle bearing (Pin crank)
grease /
▲
●
▲
O-ring (Pin crank, Needle bearing)
▲
●
▲
Spider
▲
●
▲
Seal (Pin crank, Needle bearing)
●
●
▲
only SC 30 D
Shaft seal (2) - FS (2)
●
●
▲
Shaft seal (1) - FS (1)
●
●
▲
G seal - FS (2)
●
●
▲
G seal - OS
●
●
▲
G seal - FS (1)
●
●
▲
Exhaust valve set
●
●
▲
O-Ring (Outlet flange)
●
●
▲
only SC 15 D
O-ring - FS (2)
●
●
▲
O-ring (Inlet flange)
●
●
▲
Tip seal set (1)
▲
●
▲
Tip seal set (2)
▲
●
▲
Pin crank set
▲
▲
▲
Air flush kit
●
●
●
●
Replace
▲
Replace if something goes wrong
Note 1: Be sure to use designated DIS exclusive grease.
Note 2 :The maintenance interval is the time interval or running hours whichever is reached first.
34
GA01423_0102 - 11/2004
Summary of Contents for SC 15 D
Page 1: ......
Page 7: ...Description SC 15 D SC 30 D Fig 3 Connections and controls SC 15 D 30 D GA01423_0102 11 2004 7...
Page 13: ...Description SC 15 D Fig 7 Dimensional drawing for the SC 15 D GA01423_0102 11 2004 13...
Page 14: ...Description SC 30 D Fig 8 Dimensional drawing for the SC 30 D 14 GA01423_0102 11 2004...
Page 30: ...Operation SC 15 D SC 30 D SC 5 D Fig 24 Position of Air Flush Port 30 GA01423_0102 11 2004...