Installation
Rotation direction of pump is clockwise viewed from motor side
Fig. 13 Check rotation direction after wiring
Operate pump with inlet opened, and check that air comes out from out
let.
If you plan to switch the pump ON-OFF with remote control, check the
pump's rotation direction before connecting it to the vacuum system.
When checking rotation direction, avoid dropping foreign matter
Caution
into inlet. Dropping foreign matter into the pump can cause failure.
Fig. 14 Avoid dropping foreign matter inside
GA01423_0102 - 11/2004