Diagnostic Information
2-7
4400-001
Service Checks
Carrier Transport Service Check
FRU
Action
1
System Board
Carrier Transport
Motor
Check the carrier transport motor connector CN5.
If connected, check for approximately 28 volts on
pins 1 and 2 or at the wire connections located on
the rear of the carrier transport motor. If voltage is
incorrect, replace the system board. If voltage is
correct, check the motor for shorts.
2
Carrier Transport
Motor
Check the motor for binds, or loose motor pulley.
A noisy or chattering motor or a motor that fails to
turn can be caused by:
•
An open or short in the motor
•
An open or short in the motor driver
on the system board
•
A bind in the carrier transport
mechanism
With the carrier transport motor cable (CN5)
disconnected from the system board, check for 0
to 16 ohms between the following pins on the
motor:
CN5-1 and CN5-2
If the readings are incorrect, replace the print
engine. Go to the
“Carrier Transport Motor
Removal” on page 4-25
.
3
Carrier Guide Rod
Clean the carrier rod.
Note: Lubricate the rod and the carrier rod bearing
surfaces with grease P/N 99A0394.
Summary of Contents for X63
Page 9: ...Safety Information ix 4400 001...
Page 16: ...1 6 Service Manual 4400 001...
Page 36: ...2 20 Service Manual 4400 001...
Page 64: ...4 18 Service Manual 4400 001 11 Remove ASF assembly...
Page 72: ...4 26 Service Manual 4400 001...
Page 74: ...5 2 Service Manual 4400 001 Logic Card Units Description P1 System Board P2 Phone Lines...
Page 75: ...Connector Locations 5 3 4400 001 Power Supply Units Description J5 System Board...
Page 76: ...5 4 Service Manual 4400 001...
Page 78: ...6 2 Service Manual 4400 001...
Page 80: ...7 2 Service Manual 4400 001 Assembly 1 Main Assembly...
Page 82: ...7 4 Service Manual 4400 001 Assembly 2 Base Unit...
Page 84: ...7 6 Service Manual 4400 001 Assembly 3 Engine...
Page 86: ...7 8 Service Manual 4400 001...