Diagnostic Information
2-39
4069-XXX
3
Autoconnect on the
Envelope Option
Check the connector for any signs of
damage to the connector or
contacts. If you find damage, replace
the damaged cable/connector
assembly. Disconnect the
autoconnect cable at J1 on the
envelope system board and
measure the following voltages:
J1-3 me5 V dc
J1-5 me5 V dc
J1-7 me24 V dc
If any of the voltages are incorrect,
replace the autoconnect
cable/connector. If the voltages are
correct, replace the envelope system
board.
FRU
Action