2-12
Print Quality Service Check
FRU / Function
Action
1
Print Cartridge
Be sure the machine contains good print
cartridges.
2
Color Print
Cartridge Cross
Contamination
Cross contamination of color inks results in
incorrect colors printed, as when green prints for
yellow, (when yellow and blue are mixed in the
print cartridge). This problem resolves quickly as
the print cartridge is used.
If cross contamination occurs, check the following:
• Maintenance station wiper for damage.
• Printhead nozzle plate was resealed with tape.
3
Printhead Carrier
Assembly
Reseat the printhead cables in the system board
and check the following parts for wear or damage:
• Print Cartridge Latch
• Latch Spring
• Carrier