![Lexington Forge LX32DV Installation And Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/lexington-forge/lx32dv/lx32dv_installation-and-operating-instructions-manual_1888249015.webp)
51D0528
15
VENT INSTALLATION
OPTIONAL TOP VENT APPLICATION
The appliance is shipped as a rear vent unit. If the installa-
tion layout requires the unit to be a top vent configuration the
appliance can be converted by the following steps.
When removing and refitting the plates and adapter be sure the
associated gaskets are undamaged and refitted as required.
1. Remove the eight (8) screws securing the flue pipe adapter
to the fireplace body.
See Figure 12.
2. Set the flue pipe adapter aside, complete with the gasket.
Do not damage the gaskets as the adapter and gasket must
be refitted.
3. Remove the eight (8) screws securing the flue pipe cover to
the top of the intake box and remove the cover and gasket.
See Figure 12.
4. Remove eight (8) screws securing the flue pipe to the back
of the intake box and remove the pipe and gasket.
See
Figure 13.
5. Replace flue pipe to top of firebox. Ensure the gasket is in
place and undamaged. Secure with eight (8) screws.
See
Figure 13.
6. Place the flue pipe cover and gasket removed in step 3 over
the flue opening in bottom of the intake box.
7. Refit the flue pipe adapter and gasket to the top of fire-
place. Secure the adapter with eight (8) screws removed
in step 1.
A f t e r c o n v e r s i o n t o t o p v e n t
configuration the 4" (100mm) flue pipe
should be concentric within the 6
5
/
8
"
(175mm) outer collar (within
1
/
4
").
W
ARNING
Figure 12 - Removing sixteen (16) Screws from
Flue Pipe Adapter and Flue Pipe Cover
Figure 13 - Removing Flue Pipe
Figure 14 - Attaching Flue Pipe to Top
Vent Configurations
Screws
Flue Pipe
Cover
Flue Pipe
Adapter
Flue
Cover
Flue Pipe
Screws
Flue Pipe
Screws