Lewmar CPX0- 500W Product Manual Download Page 7

Lewmar CPX 0 ref B10408 iss.2 

|  

7

5- Electrical wiring

MODEL

CABLE SIZING FOR LENGTH OF CABLE RUN

up to 7 m

up to 23 ft

7 - 15 m

23 - 50 ft

500W

16 mm²

6 AWG

25 mm²

4 AWG

700W

10 mm²

8 AWG

16 mm²

6 AWG

5.1 Electric cable selection

Lewmar recommends the installer source and install cable that meets the requirements of the standards and 

regulations relevant to the installation and codes of practice.
The cable table gives recommended cable sizes based on total length of cable required, from the battery,  

following the route of the cables to the windlass and back.

5.3 Control switch installation

The unit is supplied with

•  Guarded rocker switch (product ref 68000593)

•  Contactor (500W- 68000939 / 700W- 68000937)

Follow the wiring diagram § 5.4-5.7
NOTE: Optional electric footswitches and remote handheld control available.  

Visit www.lewmar.com for more information 

Contactor box used in some installation refer to wiring diagram § 5.5 and § 5.6 

Optional wireless remote also available See table below for models and references

WIRELESS REMOTE  

(3 BUTTON WINDLASS ONLY)

WIRELESS REMOTE  

(5 BUTTON WINDLASS & THRUSTER)

68000967

68000968

Windlass performance is directly related to 

cable size and length. Voltage drop over the 

complete wiring run must not exceed 10%.

NOTE: In a multi station installation all switches must be wired in a parallel circuit.

DO NOT confuse cable length with 

the length of the vessel

5.2 Wiring

Plan the installation to suit the controls and give the operator a full view of the windlass. The wiring system 

should be of the fully insulated type, which avoids possible electrolytic corrosion problems. We recommend the 

use of type III stranded, tinned copper wire with copper crimp terminals. Most modern installations are negative 

return (negative ground) but polarity should be checked.
Short-circuit protection, in the form of the circuit breaker provided must be built into the windlass wiring circuit.

•  Circuit breaker supplied:  

CPX0-500W 

70A (Part No 68000240) 

CPX0-700W 

90A (Part No 68000349)

•  The circuit breaker should be positioned close to the 

battery in a dry, readily accessible place.

•  The breaker must be manually reset should an over-

load occur that causes it to trip to the off position.

If you are not sure you understand these guidelines, seek professional help. Ensure that the installation com-

plies with USCG, ABYC, NMMA or other local regulations.

 

⚠ WARNING!

 

‣ When wiring Lewmar electric motor into the ship’s 

electrical system the following caution must be 

taken.

 

‣ When tightening the front nut hold the back nut 

with a separate wrench to make sure the back 

nut does not turn. If the back nut turns, serious 

damage will occur, voiding Lewmar’s warranty on 

the electric motor.

5.4 Electric motor terminal connections

DO NOT overtighten electric motor terminal nuts.

Summary of Contents for CPX0- 500W

Page 1: ...CPX 0 Windlass Product manual Owners Installations Operation servicing manual...

Page 2: ...ons 135 5 5 16 194 7 67 2 P W D D mm D inch P mm P inch W mm W inch 68001126 6mm 7mm 1 4 Gypsy kit 12 mm 1 2 3 Strand and 8 Plait 6mm DIN 766 6 0 236 18 5 0 728 20 4 0 803 6 mm ISO 4565 6 0 236 18 0 7...

Page 3: ...indlass and anchor rope chain and anchor during operation Severe bodily harm would result Ensure there are no swimmers or divers nearby when dropping anchor When the Windlass is not in use the anchor...

Page 4: ...r and the chain locker below Allow for the rotation of the manual operating lever 2 If possible select a flat area of deck If the deck is not flat care must be taken to ensure that the windlass base i...

Page 5: ...your template and after you have checked all the above and below deck requirements cut the following holes Using a 10mm 3 8 diameter drill make the 4 holes for the mounting studs 18mm 3 4 and 14mm 9...

Page 6: ...silicone or other rubbery type sealant it is advisable to allow curing of the sealant before final tightening of the mounting nuts M8 Washer M8 Nut 4 8 Loading rope chain For safety and performance Le...

Page 7: ...itches must be wired in a parallel circuit DO NOT confuse cable length with the length of the vessel 5 2 Wiring Plan the installation to suit the controls and give the operator a full view of the wind...

Page 8: ...ith any accessories Electric Switches See www lewmar com UP DOWN Remote Handheld Control See www lewmar com Rocker Switch 68000593 UP DOWN Circuit Breaker See 5 3 Battery 12 VDC Contactor 68000939 Ree...

Page 9: ...is used Installation instructions are supplied separately with any accessories ON Electric Switches See www lewmar com UP DOWN Remote Handheld Control See www lewmar com Rocker Switch 68000593 UP DOW...

Page 10: ...ies ON Electric Switches See www lewmar com UP DOWN Remote Handheld Control See www lewmar com Rocker Switch 68000593 UP DOWN Circuit Breaker See 5 3 Battery 12 VDC Contactor 68000937 Thermal Switch T...

Page 11: ...any accessories Optional accessories ON Electric Switches See www lewmar com UP DOWN Remote Handheld Control See www lewmar com Rocker Switch 68000593 UP DOWN Circuit Breaker See 5 3 Battery 12 VDC C...

Page 12: ...attery power Observe maritime anchor deployment safety rules 2 WARNING Trapping crushing or entanglement danger whiIst operating windlass manually or under power WARNING Isolate Turn off the windlass...

Page 13: ...e damage to topside As anchor approaches the vessel use careful adjustments of controls to avoid damaging vessel start and stop the windlass to bring the anchor slowly into the bow roller Pulling the...

Page 14: ...re they are sound and corrosion hasn t set in Tighten if necessary and protect if required Check mounting studs are firmly clamped and tighten if required Check rode and splice for wear Check gypsy as...

Page 15: ...e proper voltage be maintained The typical operating voltage range at the motor is 10 5 14 Volts constant low voltage will damage motor Ensure electrical cable size is large enough to handle the curre...

Page 16: ...16 16 2 18 23 8 22 12 10 6 7 4 21 20 26 13 25 1 3 15 24 11 14 5 9 GB 9 Part List...

Page 17: ...6 1 66000772 Cone and washer kit 2 1 8 1 10 1 66000600 Control arm kit 1 1 3 1 15 1 66000773 Mounting kit 7 1 14 1 66000774 Driveshaft kit 4 1 9 1 11 1 23 1 24 1 68001123 8mm 5 16 Gypsy and stripper k...

Page 18: ...commercial or charter applications Anchor rodes C LIABILITY i Lewmar s liability under this warranty shall be to the exclusion of all other warranties or liabilities to the extent permitted by law In...

Page 19: ...Lewmar CPX 0 ref B10408 iss 2 19 NOTES...

Page 20: ...tribution Lewmar Navtec Southmoor Lane Havant Hampshire PO9 1JJ UK Tel 44 0 23 9247 1841 Fax 44 0 23 9248 5720 Email info lewmar com USA Lewmar Navtec 351 New Whitfield Street Guilford CT 06437 USA Te...

Reviews: