Message/Problem 

Possible Solution

The aa550 is not faulty if these messages are displayed.

 The diagnostics help identify problems with installation, the battery, 

the solenoid and the sensor and windlass rotation.  Some of the messages appear when you try to operate the AA550 but others 

only appear briefly when the AA550 is turned on.  Always check for the diagnostic messages by switching the AA550 off and 

then on again. Use the table below to help identify a problem and provide a possible solution. If you cannot resolve the prob-

lem, contact your supplier for further information

.

e

LeCTRONIC 

d

IagNOSTICS

P

aRT 4 - TROUBLeSHOOTINg & MaINTeNaNCe

Definitions 

  SoL

 = Solenoid, 

SeN 

= Sensor, 

Lo Pr

 = Low Power

  

3.  

Lo Pr 

+ a number

Displayed when the Up or 
Down button is pressed. The 
AA550 will not operate the 
windlass. 

Low power to the AA550.  To check the voltage received by the AA550, turn the AA550 
off,  and press and hold the Down button.  The voltage will display on the LCD.  Check the 
battery voltage output.  Check wiring for loose connections.  Check the cable size.  If the 
cable is the wrong size there may be voltage drop between the battery and the AA550. See 
the cable specifications on page 2 and the minimum voltages on page 7. 

SeN and Load messages:  When these messages are displayed the aa550 will operate the windlass up and down manually 
but the auto function will not work and the count will not be accurate. 

6. 

 SeN 1

Displayed briefly when the 
AA550 is turned on and 
when it is operated manually.  
Auto does not work. No sen-
sor pulse. 

1.  

Load 

Displayed briefly when the 
AA550 is turned on and 
when it is operated manually.  
The Auto function does not 
work. 

2. 

 LoC

Displayed when a button is 
pressed. The AA550 will 
not operate.

7.  

SeN 2

Displayed briefly when the 
AA550 is turned on and when 
it is operated manually. Auto 
does not work. No sensor 
pulse.

8.  

SeN 3

Displayed when the AA550 is 
operated manually. Auto does 
not work.  No sensor pulse.

The sensor wires are disconnected or the red and black sensor wires are shorted together. 
AA550 will operate the windlass up and down but there will be no count displayed on the 
LCD.  Check sensor wiring and installation.  When fixed reset the AA550 to zero twice.  The 
anchor must be docked. To reset to zero - press and hold the ON/OFF button.  Release when 
the display shows 0.0. 

The load sensor wires are not connected to the motor. Use the AA550 manually and check the 
load wire connections.  If using an all-chain rode check that the AA550 is calibrated correctly 
for all-chain.  When fixed reset the AA550 to zero. The anchor must be docked. To reset to 
zero - press and hold the ON/OFF button.  Release when the display shows 0.0. The count will 
not be correct until the problem is fixed.  

The safety lock is on.  Hold down the Mode button to release the safety lock and then operate 
as normal.

5.  

SeN

Displayed when attempting 
to use the Auto function.

Use the AA550 up and down manually and check for the specific sensor error. SEN1 - 
SEN5. Refer to the notes 6-10 below.

4.  

OFF

Displayed when attempting 
to use the Auto function.

No setting has been entered for the rode to be released so the Auto function cannot operate. 
Enter a length of rode for release and the system will operate normally.  (Refer page 10 Opera-
tion Manual).

The black sensor wire is shorted to ground.  AA550 will operate the windlass up and down 
but there will be no count displayed on the LCD.   Check sensor wiring and installation.  
When fixed reset the AA550 to zero twice.  The anchor must be docked. To reset to zero 
- press and hold the ON/OFF button.  Release when the display shows 0.0. 

No signal from the sensor to the AA550. Either there is no magnet, the gap between the 
magnet and sensor is too big or the sensor signal is out of tune because of testing during 
installation.  AA550 will operate the windlass up and down but there will be no count dis-
played on the LCD.  Try resetting the AA550 by running the windlass up and down for 10-15 
seconds.  If the message still appears check the magnet and the gap and alignment between 
the magnet and sensor.  Check sensor wiring and installation and check for damage to the 
sensor and magnet.   When fixed reset the AA550 as above.  To reset manually the anchor 
must be docked and the AA550 reset to zero twice. To reset to zero - press and hold the ON/
OFF button.  Release when the display shows 0.0. 

8

Summary of Contents for AA550

Page 1: ...and rode and then tested in a safe environment Refer to the Operation Manual Part 2 for calibration and testing instructions 12 All installations must be carried out in accordance with USCG ABYC NMMA...

Page 2: ...e windlass requires a good quality properly fitted bow roller and a swivel should be connected to the anchor where it joins the chain TECHNICAL SPECIFICATIONS AA550 Power Supply 12V or 24V DC Current...

Page 3: ...es and drilling instructions are supplied for some windlasses Note The Lofrans Project 1000 and 1500 windlasses are predrilled for magnet installation in the bottom of the chainwheel Invert the chainw...

Page 4: ...ded in the standard kit Check with your supplier AutoAnchor also makes a flat sensor 9045 that can be fixed to the exterior housing of the windlass See Fig 7a or inside the windlass housing See Fig 7b...

Page 5: ...pace between the chainwheel and the windlass housing the sensor can be fitted externally See Fig 10a The only other option is to fit the sensor using a sensor holder as for an all chain system see the...

Page 6: ...nsulated to prevent short circuits and installed no closer than 1 ft 300mm away from the sensor head To reduce the potential for interference all cables must be located at least 1 5ft 500mm away from...

Page 7: ...r terminals The connectors supplied have a 1000 Ohm resister prefitted If you do not use these connectors a 100mA fuse must be fitted The joins should be soldered or crimped and sealed If the load sen...

Page 8: ...n but there will be no count displayed on the LCD Check sensor wiring and installation When fixed reset the AA550 to zero twice The anchor must be docked To reset to zero press and hold the ON OFF but...

Page 9: ...iring and check the direction of the windlass rotation 12 SoL uP or SoL dn Displayed briefly when the AA550 is turned on The AA550 will not operate the windlass SoL uP The Up orange wire is not connec...

Reviews: