ZONE RESPONSE TIME
All zones, in the
Omni
,,HDUHVHWWRDPLOOLVHFRQG¿[HGUHVSRQVHWLPH
ZONE TYPES
ZONE TYPE
NUMBER
DESCRIPTION
ENTRY/EXIT
0
Entry/Exit
PERIMETER
1
Perimeter
NIGHT INT
2
Night Interior
AWAY INT
3
Away Interior
LATCH PERIM
6
Latching Perimeter
LATCH NIGHT INT
7
Latching Night Interior
LATCH AWAY INT
8
Latching Away Interior
PANIC
16
Panic
POLICE EMERG
17
Police Emergency
SILENT DURESS
18
Duress
TAMPER
19
Tamper
LATCH
TAMPER
20
Latching
Tamper
FIRE
32
Fire
FIRE EMERG
33
Fire Emergency
GAS
34
Gas
Alarm
AUX EMERG
48
Auxiliary Emergency
7528%/(
7URXEOH
FREEZE
54
Freeze
WATER
55
Water
FIRE TAMPER
56
Fire Tamper
AUXILIARY
64
Auxiliary
KEY SWITCH
65
Keyswitch Input
SHUNT LOCK
66
Shunt Lock
(;,77(50,1$7(
([LW7HUPLQDWH3XVKEXWWRQ
(1(5*<6$9(5
3URJUDPPDEOH(QHUJ\6DYHU0RGXOH
OUTDOOR TMP
81
Outdoor Temperature
TEMPERATURE
82
Temperature
TEMP
ALARM
83
Temperature
Alarm
HUMIDITY
84
Humidity
ER OUTDOOR TMP
85
Extended Range Outdoor Temperature
ER TEMPERATURE
86
Extended Range Temperature
ER TEMP ALARM
87
Extended Range Temperature Alarm
LATCHING ZONE TYPES
:KHQDQ\GHYLFHRWKHUWKHQ),5(RU*$6LVFRQQHFWHGWR6:,7&+9RUD6ZLWFKHG3RZHU2XWSXWWKH]RQHPXVWEHFRQ¿JXUHG
as one of the LATCHING ZONE TYPES (latching perimeter, latching night interior, latching away interior, and latching tamper).
LATCHING ZONE TYPES ignore the status of that zone during power cycles.
8VHGSULPDULO\ZKHQWKH),5($/$509(5,),&$7,21IHDWXUHLVEHLQJXVHGRULIPRUHWKDQRQHDUHDLVEHLQJSURWHFWHG7KLVW\SH
ZLOOLJQRUHWKHVWDWXVRI/$7&+,1*=21(6LH*ODVVEUHDN'HWHFWRUVZKHQWKHSRZHULVVZLWFKHGWRUHVHWGHYLFHV
Page 39
WEB
VERSION