7 INSTALLATION
10
L1 L2 PE
L1 L2 PE
L1 L2 PE
Circuit Breaker Options Table
Output Amperage Amps
32A
48A
Circuit Breaker Options Amps
40A
60A
7.1 Wiring
120V
NEUTRAL
(NOT USED)
L3 (NOT USED)
L1
L2
GND
120V
120V
208V 3-Phase, Wye-Connected -
WARNING: The 208V feed is from a
y-connection power grid, and the AC charger
can connect to L1 and L2, L2 and L3, L1 and
L3. Earth ground must be connected to neutral
at only one point, usually at the breaker panel.
Leave the unused leg open. Do not connect it to
a Neutral bar, or to ground. Be sure the center
point is Earth ground somewhere in the system.
240V Single Phase -
WARNING: The two phases used must
each measure 120V to Ground. Earth
ground must be connected to neutral at
only one point, usually at the breaker panel.
120V
240V
NEUTRAL
120V
L1
L2
GND
(NOT USED)