background image

12

Quick Tips

If your switch is not performing as expected, visit  
leviton.com/decorasmart or contact technical services.

 

 Status light is on but light is off and does not respond:

 

 

- Check wiring to confirm hot, neutral and load.

 

 

- Ensure the white conductor is a neutral.

Factory default

To reset the switch to factory settings and place into joining mode:

1.

    Hold the top of the paddle for a total of  

14 seconds.

2.

   After the first 7 seconds the light turns  

amber.  Continue to hold.

3.

   After a total of 14 seconds, 

the status light will quickly 
flash red/amber.

4.

   Release the top of the paddle 

and the switch will reset.

 

WEB 

VERSION

Summary of Contents for Decora Smart DG15S

Page 1: ...Getting Started Guide Cat No DG15S SWITCH WEB VERSION...

Page 2: ...WEB VERSION...

Page 3: ...3 See the complete line of Zigbee enabled dimmers switches and plug ins leviton com decorasmart Welcome to the Decora Smart family of Zigbee enabled devices WEB VERSION...

Page 4: ...We are here to help The Decora Smart Switch with Zigbee technology is designed for use with modern Zigbee hubs Using mesh networking technology Zigbee provides quick reliable secure communication to a...

Page 5: ...s If you have further questions please contact technical services at dssupport leviton com for more information 5 RATINGS LED CFL 5A 600W 120VAC 60Hz Resistive 15A 120VAC 60Hz Incandescent Halogen 180...

Page 6: ...6 Features Rocker Manually turn light on The bottom of the paddle turns the light off Status light Illuminates when load is off WEB VERSION...

Page 7: ...s are controlled from more than one location you will need a DD0SR 1 remote See the DD0SR 1 installation instructions for wiring instructions Zigbee is a mesh network It must be installed within 30 ft...

Page 8: ...touching 3 Restore power Carefully test wires with voltage tester to nd the hot wire 4 Turn off power at the circuit breaker 5 Mark the following wires Identify your wires If your wall box looks diff...

Page 9: ...on at a time 2 Connect wires as shown 3 Secure wire connections with an electrical connector Wire your switch If your wall box looks different consult an electrician BK YL RD RD WH H O T G R O U N D N...

Page 10: ...itch is ready to be enrolled Turn off power at circuit breaker before completing the switch installation 2 Gently push wires into wall box Screw switch to box 3 Snap on Decora wallplate Restore power...

Page 11: ...lly start or stop joining mode perform the following steps 1 Hold the top of the paddle for 7 seconds Status light will turn amber 2a To start joining mode tap the top of the paddle 1 time The status...

Page 12: ...eutral and load Ensure the white conductor is a neutral Factory default To reset the switch to factory settings and place into joining mode 1 Hold the top of the paddle for a total of 14 seconds 2 Aft...

Page 13: ...esult This module will not control lighting that is used with electronic low voltage and high frequency power supply transformers nor high pressure discharge lamps HID lighting This includes mercury v...

Page 14: ...radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not...

Page 15: ...WEB VERSION...

Page 16: ...m EMAIL dssupport leviton com Leviton Manufacturing Co Inc 201 North Service Road Melville NY 11747 Telephone 1 800 824 3005 Visit Leviton s website at www leviton com 2020 Leviton Manufacturing Co In...

Reviews: