a
b
c
M16
5
© 2020 · INST_PSA 11/20 · www.halfen.com
HALFEN PSA
Assembly Instructions
Deutsch
English
General information
Make sure the anchors are clean; remove foreign substances, lubricants etc., to ensure a good bond with the concrete.
Pour the concrete carefully, avoid direct contact between the vibrator and the anchor.
We recommended additional wire-tying of the anchors to the reinforcement.
Fixing anchors for PSA applications are installed flush with the surface.
Remove fixing elements directly after removing the formwork.
Installation of the fi xing anchor for use as a PSA attachment system
2.) Preparation
3.) Attach the PSA eye-bolt
Case A
with plastic fi xing plate
Remove the formwork
Remove the fi xing plate
Fixing plate
Type 2275
Case B
fi xing with bolt
Case C
with thread adapter and hexagonal headed bolt
Thread adapter
Type 2600
Un-screw the bolt
Remove the formwork
Screw in the
PSA eye-bolt
a) Remove bolt
b) Remove formwork
c) Un-screw the thread adapter
1.) Fixing to formwork
M8