background image

a

b

c

M16

5

©  2020 · INST_PSA 11/20  · www.halfen.com

HALFEN PSA 

Assembly Instructions 

Deutsch

English

  

General information

Make sure the anchors are clean; remove foreign substances, lubricants etc., to ensure a good bond with the concrete.

Pour the concrete carefully, avoid direct contact between the vibrator and the anchor. 

We recommended additional wire-tying of the anchors to the reinforcement.

Fixing anchors for PSA applications are installed flush with the surface.

Remove fixing elements directly after removing the formwork.

Installation of the fi xing anchor for use as a PSA attachment system

2.) Preparation

3.) Attach the PSA eye-bolt

Case A
with plastic fi xing plate

Remove the formwork
Remove the fi xing plate

Fixing plate
Type 2275

Case B
fi xing with bolt

Case C
with thread adapter and hexagonal headed bolt

Thread adapter
Type 2600

Un-screw the bolt
Remove the formwork

Screw in the 
PSA eye-bolt

a) Remove bolt
b) Remove formwork
c) Un-screw the thread adapter

1.)  Fixing to formwork

M8

Summary of Contents for HALFEN PSA

Page 1: ...HALFEN PSA INST_PSA 11 20 Assembly Instructions Montageanleitung Attachment system for personal fall protection Anschlagsystem f r pers nliche Sicherheitsausr stung D GB...

Page 2: ...anchor in concrete approved according to ETA 13 0222 with xed cap for identi cation as a PSA point RUD PSA Inox Star eye anchor M16 as xing point for PPE personal protection equipment The suitability...

Page 3: ...01 3 16 21 3 Eye bolt anchor Inox Star M16 A 49 mm B 17 mm C 15 mm D 35 mm E 36 mm G 38 mm K 65 mm L 24 mm M 16 mm N 10 mm S 24 mm Weight 310 g L t hef b d nom 3 2020 INST_PSA 11 20 www halfen com HAL...

Page 4: ...k 6 kN for the rst person and an increase of FEk 1 kN for a further person To calculate the design values of the loads FEd the characteristic values of the loads have to be multiplied by a partial saf...

Page 5: ...Fixing anchors for PSA applications are installed flush with the surface Remove fixing elements directly after removing the formwork Installation of the xing anchor for use as a PSA attachment system...

Page 6: ...using an offset socket wrench and using a torque spanner set to Tinst 60Nm If required as an extra precaution apply a liquid screw locking agent Loctite or similar When used as an temporary installed...

Page 7: ...00005 Sealing cap ribbed Article name 6315 16 Material plastic Colour light grey Order no 0741 130 00003 Alternative methods for xing the T FIXX to formwork Fixing anchor T FIXX T FIXX M16 110 A4 FP C...

Page 8: ...the installation instructions A copy of this document must be given to the client in case of any forthcoming noti cation requirements by an approved building authority City date Stamp signature Site p...

Page 9: ...Ringschraube RUD PSA Inox Star M16 als Anschlagpunkt Anschlag einrichtung einer PSA Die Eignung des Systems wurde im Hinblick auf die statische Belastbar keit durch die Pr f und Zerti zie rungsstelle...

Page 10: ...3 16 21 3 Ringschraube Inox Star M16 A 49 mm B 17 mm C 15 mm D 35 mm E 36 mm G 38 mm K 65 mm L 24 mm M 16 mm N 10 mm S 24 mm Gewicht 310 g 10 2020 INST_PSA 11 20 www halfen com Deutsch English HALFEN...

Page 11: ...e Einwirkung von FEk 6 kN und f r jede weitere Person eine Erh hung von FEk 1 kN Person Zur Ermittlung der Bemessungswerte der Einwirkungen FEd sind die charakteristischen Werte der Einwirkungen mit e...

Page 12: ...en oberfl chenb ndig eingebaut Haltescheiben unmittelbar nach dem Ausschalen herausdrehen Einbau des H lsenankers als Anschlagsystem f r PSA 2 Vorbereitung zur Montage 3 Einschrauben der PSA Ringschra...

Page 13: ...hmomentschl ssel unter Aufbringung eines Anzugsmoments Tinst 60 Nm Als zus tzliche Sicherung ggf ein fl ssiges Schraubensiche rungsmittel Loctite o verwenden Verwendung als tempor r angebrachte PSA Ha...

Page 14: ...Nr 0021 030 00005 Verschlussstopfen mit Lamellen Artikelbezeichnung 6315 16 Material Kunststo Farbe lichtgrau Bestell Nr 0741 130 00003 Hilfsmittel zur Befestigung des T FIXX an der Schalung H lsenan...

Page 15: ...er Einhaltung aller Bestimmungen gem Montageanleitung montiert wurde Diese Bescheinigung ist dem Bauherrn als Kopie zur ggf erforderlichen Weitergabe an die zust ndige Bauaufsichtsbeh rde auszuh ndige...

Page 16: ...viat com France 18 rue Goubet 75019 Paris Tel 33 1 44 52 31 00 Email info fr leviat com Germany Liebigstrasse 14 40764 Langenfeld Tel 49 2173 970 0 Email info de leviat com India 309 3rd Floor Orion B...

Reviews: