27
Maintenance and cleaning
day. You do not need to stay with the oven during this
process. You can easily go home.
When the decalcifying is ready, then all functions are
switched off.
The mastermind display will be empty.
The digital will show B4-4.
You can switch on the oven again by pressing the I-0
button on the display. When the decalcifying process has
been started, the whole programme needs to be followed
to the end.
9.4
Maintenance water softener
Leventi advises to always apply a water softener. This will
prolong the lifespan of your oven (and particularly the
boiler versions).
When you have connected your oven to a water softener,
then on average this should be descaled at least every
two weeks to ensure a proper working. Therefore follow
the operation manual of your water softener.
Flushing the manual water softener
Below text is a short manual for the manual water
softener.
Important: NEVER remove the resin grains in your water
softener!
During the rinsing process
there is no water
connection to the
connected machine.
Keep this in mind.
Hang the end of the hose E
in a bucket.
Hang the end of the hose F
in a drain.
Turn the taps C and D (in
the direction of the arrows).
There will be water
pressure on hose E (max 2
liters).
Open the lid G
Fill the water softener with
one to one and a half kilos of
salt.
Close the lid G
Turn the tap C back (left,
according to the arrow).
There will be salt water
coming out of hose F
Wait for 2 hours.
Turn tap D back (left,
according to arrow).
The water softener is ready
for use.
Salt type: the salt will be used during the rinsing process
to clean the water softener. The salt should never be
present during normal use. Therefore use the two hour
period (50 liters of flushing water). After the rinsing
period the water coming out of hose F SHOULD be sweet
tasting.
9.5
Small maintenance.
9.5.1 Change the filter of the air cooler
The filter is located
at the shaft under
the operation panel.
This shaft contains a
filter for cooling the
air in the technical
area of the oven.
This filter should be
cleaned regularly. Check this filter at least every two
weeks.
9.5.2 Changing the oven lighting
Type bulb, 12V,
20W,
max.res.300°
Celcius,
beamangel 38°.
Article code:
05001232000
E
F
1
C
D
B
A
F
G
H
1 k
g
BR
O
XO
2
3
4