9
will be provided by DHCP server. If the DHCP client is enabled, the IP address is provided by DHCP server, so user
should make sure there is a DHCP server in the net before you enable this function.
5.5 Password Setting
In this page, we could change the password. The password must be ‘a’-‘z’, ‘A’-‘Z’, ‘0’-‘9’ and ‘_’.
The max length is 16 characters. In this web, we do not support user purview configuration, and only support one
user name setting. We can't not change user name in the web.
5.6 Converter Configuration
Jumbo Frame (9K):
If enable this function, the media converter could pass the max 9KB packet.
Link Transparent: Only if link transparent is enabled, the Remote Fault Detect and Link Loss Carry Forward will take
effect.
Remote Fault Detect:
If enable this function, when fiber port enable TS-1000 and receive OAM pkt.
The OAM Media Converter will set local UTP port link up or link down according to remote
device’s UTP port link
Status:
This function need enable link transparent first.
Link Loss Carry Forward: If enable this function, when the UTP port link down, the fiber port will be forced link down.
And the fiber will be resuming when UTP port link up. This function need enable link transparent first.
Forward CRC Error Frame:
If enable this function, the CRC error packet will be pass, otherwise, the CRC error
packets will be dropped.