C
OMPLIANCES
iv
CE Mark Declaration of Conformance for EMI and
Safety (EEC)
This information technology equipment complies with the requirements of the Council
Directive 89/336/EEC on the Approximation of the laws of the Member States relating to
Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain
voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the
compliance with these Directives, the following standards were applied:
Warning:
Do not plug a phone jack connector in the RJ-45 port. This may damage this device.
RFI Emission:
• Limit class A according to EN 55022:1998
• Limit class A for harmonic current emission according to
EN 61000-3-2/1995
• Limitation of voltage fluctuation and flicker in low-voltage supply
system according to EN 61000-3-3/1995
Immunity:
• Product family standard according to EN 55024:1998
• Electrostatic Discharge according to EN 61000-4-2:1995
(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)
• Radio-frequency electromagnetic field according to EN 61000-4-3:1996
(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)
• Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/
DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)
• Surge immunity test according to EN 61000-4-5:1995
(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)
• Immunity to conducted disturbances, Induced by radio-frequency
fields: EN 61000-4-6:1996 (0.15 - 80 MHz with
1 kHz AM 80% Modulation: 3 V/m)
• Power frequency magnetic field immunity test according to
EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)
• Voltage dips, short interruptions and voltage variations immunity test
according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%
Reduction @500 ms, >95% Reduction @5000 ms)
LVD:
• EN 60950-1:2001
Summary of Contents for GSW-1676
Page 1: ...GSW 1676 GSW 2476 User Manual...
Page 2: ......
Page 16: ...FIGURES xvi...
Page 58: ...CONFIGURING THE SWITCH 6 10 Figure 6 3 Status Overview...
Page 62: ...CONFIGURING THE SWITCH 6 14 Web Click STATUS Statistics Figure 6 4 Port Statistics...
Page 71: ...STATIC MAC 6 23 Figure 6 13 Counter Configuration...
Page 109: ...802 1X 6 61 Figure 6 32 802 1X Configuration...
Page 113: ...802 1X 6 65 Web Click 802 1X Statistics Figure 6 33 802 1X Statistics...
Page 128: ...TROUBLESHOOTING A 4...
Page 138: ...SPECIFICATIONS C 4...
Page 144: ...GLOSSARY Glossary 6...
Page 148: ...INDEX Index 4...
Page 149: ......
Page 150: ...GSW 1676 GSW 2476 E052010 CS R02 149100011100H...