background image

*  Sensor with “S“ type output, for each flash of the LED switches its output on for approx. 3 ms. This period is 

sufficiently short to avoid unwanted switching of relay contacts. For binary inputs, we recommend to set the filter so 

as not to respond to pulses shorter than 3 ms.

Indicator

 

Function

Orange LED

Continuous light

 – Sensor is closed (switched ON)

Dark

 – Sensor is open (switched OFF)

Rapid  lashing

 

(period 0.2 sec.)

 

*

 

– Unrecognized upper and lower limits of setting mistake

 

Slow  lashing 

(period 0.8 sec.)

 

– Short circuit at sensor output

S

TaTuS

Sensing 

 

b)

7

Put the level of the measured medium in the state 

above the upper edge

 of the 

sensor in the tank or in the gauge-pipe.

Attach the magnetic pen MP-8 to the sensitive spot 

M

for 

maximum 2 seconds

.       

When the LED goes out, the sensor is in the state open.

After  removal  of  the  magnetic  pen  check  the  status  of  orange  lights:

If the LED lights or is flashing rapidly (0.2 s), go to step 4.

If the LED doesn´t light, you must repeat step 2 so as to observe the limit 

of  4  seconds  attaching  magnetic  pen. 

If the LED doesn´t light, settings of the sensor is correct.  

If the LED lights, the sensor was set incorrectly and you must repeat the 

procedure from step 1.

If the LED is flashing, the sensor didn´t recognize upper and lower limits.               

In this case, first verify that at the step 1 the level of the measured medium 

was below the lower edge of the sensor and at the step 3 the level of the 

measured medium was above the upper edge of the sensor. Then make sure 

that the thickness of the gauge-pipe wall or the tank wall does not exceed 

the limit specified in the Technical specifications (p. 2). If not, check there 

isn´t  a  thick  layer  of  sediment  on  the  inner  wall  of  the  tank  or  the  gauge-pipe.                                                                                                            

1.

2.

3.                         

4.

5.

6.

 Mode C 

(normally closed) 

Put the level of the measured medium in the state 

below the lower edge

 of the 

sensor in the tank or in the gauge-pipe.

Attach the magnetic pen 

PM-8 

o

n

 the sensitive spot 

M

 

for 

minimum 4 

seconds

. When the LED lights up, the sensor is in the state closed.

Afte                               

r removal of the magnetic pen check the status of orange lights: 

-

-

                               

-

-

-

After this settings the sensor responds to the level immersion and emersion in the 

upper half of the sensing area and the 

hysteresis

 size 5 mm (1/8 of the distance 

between  the  bottom  and  the  top  of  the  sensor).              

Summary of Contents for NC30-10

Page 1: ...shed in this manual before the rst use of the sensor Keep the manual at a safe place The manufacturer reserves the right to implement changes without prior notice INSTRUCTION MANUAL industrial electro...

Page 2: ...s 3 Recommended range of application 4 Unsuitable range of application 4 Procedure for put sensor into operation 4 1 Installation 4 2 Electrical connection 5 3 Sensor settings 6 Status signalization 7...

Page 3: ...Switching current Min Max Output type P open collector PNP Output type S two wire el switch 100 mA 3 3 40 mA Remanent voltage ON state Output type P open collector PNP Output type S two wire el switch...

Page 4: ...cable LED Electrode Sensitive spot for setting Detection of various types of liquids water disel oil cooling liquids water solutions some types of solvents It is suitable for glass or plastic gauge p...

Page 5: ...the detec ted medium see technical data the maximum is 8 mm The sensor is fixed to the gauge pipe or tube by means of two plastic straps 2 5 mm width The cable should be vertically down wards oriented...

Page 6: ...ype output Positive pole U of power supply is connected to brown wire or pin connector No 1 negative pole is connected to blue wire or pin connector No 3 Load relay is connec ted to black wire or pin...

Page 7: ...he measured medium was below the lower edge of the sensor and at the step 3 the level of the measured medium was above the upper edge of the sensor Then make sure that the thickness of the gauge pipe...

Page 8: ...light settings of the sensor is correct If the LED lights the sensor was set incorrectly and you must repeat the procedure from step 1 If the LED is flashing the sensor didn t recognize upper and low...

Page 9: ...rode polarity overvoltage and short term current overload on the output Electromagnetic compatibility is provided by conformity with standards SN EN 55022 B SN EN 61326 1 SN EN 61000 4 2 SN EN 61000 4...

Page 10: ...es outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel au...

Page 11: ...ICON PROCESS CONTROLS Corrosion Free Liquid Process Instrumentation Equipment Flow Level Pressure Temperature...

Reviews: