Technical Data
Leuze
electronic
14
ODS 96
Leuze electronic
4
Technical Data
4.1
Optical Data
4.2
LED Indicators
ODS 96
M/V, M/D, M/S
ODS 96
M/V, M/D, M/S Laser
Optical data
Measurement range
1
1.Reflectance factor 6%...90%, over the whole temperature range, measured object
50x50 mm
2
100-600 mm
200-2000 mm
Resolution
0,5 mm
5 mm
Light source
LED (modulated light)
Laser (modulated light)
Wavelength
880 nm (infrared)
660 nm (visible redlight)
Light-spot diameter
approx. 10 mm (over whole
measuring range)
divergent min. 3x12 mm in
2000 mm distance
Error limits
Absolute measure-
ment accuracy
± 2%
± 2%
Repeatability
2
2.Same object, measured object
50x50 mm
2
± 0,5%
± 0,5%
b/w detection thresh-
olds (6%/90%)
1%
1%
Timing
Switching frequency
20-100 Hz
10-100 Hz
Response time
100 ms
Delay before start-up
300 ms
Table 1: Optical data, Error limits, Timing
LED
ODS 96 M/V, M/V Laser;
ODS 96 M/D, M/D Laser
ODS M/S, M/S Laser
teach-in on GND teach-in on +U
B
teach-in on GND teach-in on +U
B
permanent
green light
Device Ready
Device Ready
flashing green
Error
Teach-in proce-
dure
1
1.The teach-in process is described in detail in section 5.3 "Teach-In"
Error
Teach-in
procedure
green off
no voltage
no voltage
yellow perma-
nent light
Object inside
teach-in measure-
ment distance
Object inside
measurement
range
yellow flash-
ing
Teach-in
procedure
Object outside
measurement
range
Teach-in
procedure
yellow off
Object outside
teach-in measure-
ment distance
no object
detected
Table 2: LED indicators