Starting up the device
Leuze electronic GmbH + Co. KG
MSI-RM2B
13
8
Starting up the device
Prerequisites:
• Protective sensors and safety relay were mounted and connected in accordance with the respective
instructions.
• Operating personnel were instructed on proper use.
• Dangerous process was switched off and the system has been protected against being restarted
again.
During start-up, test the function of the safety relay (see chapter 9 "Testing").
8.1
Switching on
Requirements for the supply voltage (power supply unit):
• Safe mains separation is ensured (acc. to EN/IEC 60742).
• Changes and interruptions of the supply voltage are handled (acc. to IEC 61496-1:2020).
• The start/restart interlock function of the connected safety sensors or safety relays is activated.
Switch on the current supply.
The safety relay is ready for use.
WARNING
Improper use of the safety relay may result in serious injury!
Make certain that the entire device and the integration of the optoelectronic protective device
was inspected by competent and instructed persons.
Make certain that a dangerous process can only be started while the safety devices are
switched on.