Electrical connection
Leuze electronic GmbH + Co. KG
MSI-RM2B
12
Table 7.1:
Terminal assignments
7.2
Circuit diagram examples
*
Spark extinction circuit, suitable spark extinction provided
Figure 7.1: MSI-RM2B safety relay with MLC 500 / MLC 300 safety light curtain
Terminal
MSI-RM2B
22
Relay contact 2 IN, NC
24
Relay contact 2 IN, NO
11
Relay contact 1 OUT
Y1
External device monitoring circuit (EDM)
n.c.
n.c.
Y2
External device monitoring circuit (EDM)
A2
0 V
B1
Sensor input channel 1, 24 V
B3
Sensor input channel 2, 24 V
14
Relay contact 1 IN, NO
21
Relay contact 2 OUT
12
Relay contact 1 IN, NC
EDM
OSSD1
MSI-RM2B
OSSD2
Start
MLC520R / MLC320R
Restart
0V
FE
FE
0V
MLC500T / MLC300T
+24V
n.c.
Test
+24V
WH
A1
A2
-K3
A1
A2
-K4
PK
GN
1
2
1
2
BU
SH
8
-W1
BU
SH
-W2
-S1
A2
5
14
B3
6
Y1
BN
B1
4
-A3
11
3
12
22
YE
-K4
-K3
21
Y2
-W1
BK
BN
5
-W2
7
2
1
-A2
4
3
2
1
-A1
24
GY
PE
+24V
0V
+24V
PE
0V
L+
L+
L-
L-
RES active
*
*