Reading techniques

The imager has a view finder that projects a
bright green aiming beam that corresponds to the
imager’s horizontal field of view. The aiming
beam should be centred over the bar code, but it
can be positioned in any direction for a good
read.

The aiming beam is smaller when the imager is
closer to the code and larger when it is farther
from the code. Symbologies with smaller bars or
elements (mil size) should be read closer to the
unit. Symbologies with larger bars or elements
(mil size) should be read farther from the unit. To
read single or multiple symbols (on a page or on
an object), hold the imager at an appropriate
distance from the target, activate the trigger, and
center the aiming beam on the symbol. If the
code being scanned is highly reflective (e.g.,
laminated), it may be necessary to tilt the code
+5° to prevent unwanted reflection.

You will find the reading fields on page 5

Testing the scanner

This bar code is for testing the scanner,
the module size is 0.5 mm (20 mil)

Code 39 bar code sample

Summary of Contents for IT 4715

Page 1: ...Leuze electronic IT 4715 Fix mounted 2D code scanner Quick start user s guide ...

Page 2: ...DS 6 IT 4715 SR 1 xxx 6 IT 4715 SF 1 xxx 7 IT 4715 FACTORY SETTINGS DEFAULT 8 CONFIGURATION 8 IT 4715 AT THE SERIAL PC INTERFACE 8 With powering over PIN 9 at TTL RS232 cable PIN9 IT 4xxx Art No 501 04586 8 With powering over the power supply at the RS 232 cable ext IT 4xxx Art No 501 03413 9 Configuration for Leuze standard protocol 9 IT 4715 to MA 41 DP k or MA 41 IS 10 IT 4715 for MA 21 11 IT 4...

Page 3: ...nner please proceed in the following way 1 Plug in the RJ 41 connector in the socket until the cable is clicked in 2 Connect the other side of the cable to your PC 3 If you use the RS 232 interface you have to check if the scanner is supported with power Please check it with the pinning on page 5 to find the right cable 4 Connect the power supply to the socket if your PC do not support the power 5...

Page 4: ...ogies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit To read single or multiple symbols on a page or on an object hold the imager at an appropriate distance from the target activate the trigger and center the aiming beam on the symbol If the code being scanned is highly reflective e g l...

Page 5: ...tor Signal Description 1 VCC IN 4 5 12 Volt DC 2 GND Ground The suitable power supply for the IT 4xxx 100 240 V 47 63 Hz is the article number 501 03403 TTL RS 232 cable PIN9 IT 4xxx Art No 501 04586 Pinning 9 pin D sub connector female at the cable 42203758 03 PIN number Signal Description 1 Shield Shield 2 TX Transmit data 5 to 5V 3 RX Receive data 5 to 5V 5 GND Signal ground 7 CTS Clear to send...

Page 6: ...Leuze electronic Quickstart guide IT 4715 Leuze electronic Page 6 Reading fields IT 4715 SR 1 xxx ...

Page 7: ...Leuze electronic Quickstart guide IT 4715 Leuze electronic Page 7 IT 4715 SF 1 xxx ...

Page 8: ...er the RS 232 or USB interface You can download this program from our homepage www leuze de With this program you can configure the IT 4715 via the PC and transmit the configuration to the device The configuration can also be stored in a file on the PC For more informations please see the user s guide IT 4600 4800 In the following the most important configurations will be shown IT 4715 at the seri...

Page 9: ...scription 1 Shield Shield 2 TX Transmit data 5 to 5V 3 RX Receive data 5 to 5V 5 GND Signal ground 7 CTS Clear to send 8 RTS Request to send PIN at power connector Signal Description 1 VCC IN 4 5 12 Volt DC 2 GND Ground The suitable power supply for the IT 4xxx 100 240 V 47 63 Hz is the Article Number 501 03403 RS 232 data transmission with 115200 Baud 8 databit 1 stopbit no parity postfixes CR LF...

Page 10: ...32 1x 501 04 442 TTL cable RS 232 ext 1x 501 03 403 power supply 1x 500 35 421 KB 021 Z 1x 500 33 638 MA 41 DP k for PROFIBUS for Interbus 500 28 994 MA 41 IS or 500 30 085 MA 41 IS PDP Pinning KB 021 Z colour Signal Pin MA 41 Brown braun RXD 2 White weiss TXD 1 Blue blau GND 4 Red rot VCC 3 Black schwarz GND Shield blank PE 21 You have to connect the IT 4715 as shown below Configuration Connectio...

Page 11: ... LF Necessary parts 1x IT 4715 XX 1 232 1x 501 04 586 TTL cable RS 232 ext 1x 500 35 421 KB 021 Z 1x 500 30 481 MA 21 100 Pinning KB021 Z colour Signal Pin MA 21 Brown braun RXD 26 White weiss TXD 27 Blue blau GND 28 Red rot VCC 30 Black schwarz GND 31 Shield blank Schirm PE 21 You have to connect the IT 4715 as shown below Configuration Connection for MA21 in default ...

Page 12: ...s described The data is transmitted to the open window at the position of the cursor You can use this mode in all standard PC programs Necessary parts 1x IT 4715 XX 1 USB 1x 501 03 404 cable USB You have to connect the IT 4715 as shown below 1 Plug in the cable of the IT 4715 in a free USB port 2 The scanner gives you an acoustic signal 3 Scan the code Configuration USB keyboard emulation with CR ...

Page 13: ...nd use baudrate 38400 8 databits 1 stopbit and no parity As postfix or terminator CR Configuration COM port emulation at the next free COM with 38400 baud 8 databit 1 stopbit no parity and CR as postfix Triggering To activate a read operation you have to send a trigger command over the RS 232 or USB interface only COM port emulation The command has to be transmitted with the baudrate parity data a...

Page 14: ... 232 TTL RS 232 50104052 IT 4715 SF 1 USB USB All devices are without cable Please order separately Accessories Accessories for series IT IT 4715 XX 1 232 031C IT 4715 XX 1 USB Art Nr Description P N Nr Picture 50103404 USB cable for IT 4600 4800 4715 and ST 2020 42206161 01E X 50104442 TTL RS 232 cable ext for IT 4715 42203758 04E X 50104586 TTL RS 232 cable PIN 9 IT 4715 and ST 2020 42203758 03E...

Page 15: ...IBUS gateway Art Nr 500 33 638 KB 021 Z cable to MA 41 for IT4xxx Art Nr 500 35 421 Connection to Interbus MA 41 IS Interbus gateway Art Nr 500 28 994 MA 41 IS PDP Interbus gateway with long data protocol Art Nr 500 30 085 KB 021 Z cable to MA 41 for IT4xxx Art Nr 500 35 421 Leuze electronic GmbH Co KG P O box 1111 In der Braike 1 D 73277 Owen Tel 49 07021 573 0 Fax 49 07021 573199 E mail info leu...

Reviews: