Sensor adjustment via teach input (pin 5)
Teach-in
To teach, a teach signal is applied to the teach input (pin 5). The duration of the
teach signal (low level on the teach input) determines the teach-in function.
NOTICE
Before a low level is applied for teaching-in functions, a high level must
be applied for at least 20 ms.
11
A
Buttons locked
B
Buttons can be operated
T
Duration of the teach signal
Duration T
[ms]
Function
20 … 80
easy Teach while the label tape is passing through
120 … 180
Static teach
220 … 280
Configure the switching behavior of the switching output: light
switching
320 … 380
Configure the switching behavior of the switching output: dark
switching
420 … 480
easyTune (-): reduce sensitivity
520 … 580
easyTune (+): increase sensitivity
620 … 680
Activate the
ALC function
720 … 780
Deactivate the
ALC function
820 … 880
Changeover of the detection process:
ultrasonic active
920 … 980
Changeover of the detection process:
optical active
1020 … 1080
Manual easy Teach mode active
1120 … 1180
Intelligent easy Teach mode active