Static teach on the label carrier without transport
With the static teach process, a one-point calibration is performed on the blank
carrier. This process is especially advantageous because no labels are lost while
teaching.
NOTICE
After the teach event is ended, the sensor does not automatically se-
lect the appropriate detection process (
ultrasonic or optical) but rather
operates with the detection process that was active before the teach
event was started.
Preparation: depending on the label size, pull off one or more labels from the car-
rier and insert the blank area into the sensor.
5
Ä
Press the teach button until the green ON LED and the yellow OUT LED flash
alternately.
Ä
Release the teach button.
ð
The sensor indicates the currently active detection process via the yellow
CLEAR LED or the yellow PAPER LED:
CLEAR LED:
ultrasonic detection process is active
PAPER LED:
optical detection process is active
NOTICE
Ä
To manually change the detection process (
press the LABEL button ("Select active detection process").
Adjusting the switching behavior of the switching output (light/dark
switching)
6
Ä
Press the teach button until only the green ON LED flashes.
Ä
Release the teach button.
The green ON LED flashes for another 2 seconds and the yellow OUT LED
indicates the changed switching behavior for 2 seconds:
– Yellow OUT LED ON: switching output, light switching (signal in the label
gap)
– Yellow OUT LED OFF: switching output, dark switching (signal on the label)
12
EN