Technical data
Leuze electronic GmbH + Co. KG
ELC 100
37
Dimensions
see chapter 12.2 "Dimensions, weight, response
time"
Weights
see chapter 12.2 "Dimensions, weight, response
time"
Tab. 12.4:
System data - transmitter
Light source
LED; exempt group in acc. with IEC/EN 62471
Wavelength
940 nm
Pulse duration
1.6 µs
Pulse pause
3.5 µs (min.)
Mean power
<50 µW
NOTICE
The UL testing only includes fire and shock tests.
Tab. 12.5:
Technical data of the electronic safety-related switching outputs (OSSDs) on the receiver
Safety-related PNP transistor out-
puts (short-circuit monitored,
cross-circuit monitored)
Minimum
Typical
Maximum
Switching voltage high active (U
v
-
1.5V)
18 V
22.5 V
27 V
Switching voltage low
0 V
+2.0 V
Switching current
50 mA
Residual current
500 µA
In the event of a failure (if the 0 V ca-
ble is interrupted), each of the outputs
behaves as a 120 kΩ resistor to U
v
. A
downstream safety PLC must not de-
tect this as a logical “1”.
Load capacity
30 nF
Load inductivity
500 mH
Permissible wire resistance for load
< 20 Ω
Note the additional restrictions due to
cable length and load current.
Permissible wire cross section
0.25 mm
2
0.34 mm
2
Permissible cable length between re-
ceiver and load
15 m
Test pulse width (1*)
200 µs
Test pulse spacing (1*)
20 ms
OSSD restart delay time after beam
interruption
100 ms
(1*) The outputs are tested cyclically (brief low or high switching). When selecting the downstream control
elements, make sure that with the parameters specified above, the test pulses do not lead to a shutdown.