QUICK START 

GUIDE

SR 15, 25C & 46C

Summary of Contents for SR 15

Page 1: ...QUICK START GUIDE SR 15 25C 46C ...

Page 2: ...2 ...

Page 3: ... 1 Secure the sensor at the desired position in the system use the adapter plate if necessary 2 Do not tighten the screws until alignment has been completed see page 6 and then check that the sensor is functioning correctly ...

Page 4: ...4 ...

Page 5: ...NSMITTER UB NC GND NC CONNECTING THE SENSOR When connecting to the PLC take into account the pin assignment specified below Available for certain variants only for further infor mation see the data sheet Activation input possible depending on variant ...

Page 6: ...6 A B C ...

Page 7: ...spot hits the reflector continue to page 9 B the light beam is directed toward the receiver The transmitter and receiver must be mounted on one axis continue to page 11 C the light beam hits the part of the object by which it is to be detected continue to page 13 ...

Page 8: ...8 ...

Page 9: ...USTMENT 1 When an object enters the light axis the yellow status LED must go out If this is not the case the sensitivity must be adjusted 2 Using the screwdriver turn the potentiometer until the yellow status LED goes out Only on variants with potentiometer ...

Page 10: ...10 ...

Page 11: ...TMENT 1 When an object enters the light axis the yellow status LED must go out If this is not the case the sensitivity must be adjusted 2 Using the screwdriver turn the potentiometer until the yellow status LED goes out Only on variants with potentiometer ...

Page 12: ...12 ...

Page 13: ...n the multiturn potentiometer counter clockwise until the yellow status LED goes out Then turn it clockwise slightly until the LED lights up again 3 Check the reproducibility by moving the object Reproducibility is given if the sensor switches at the desired position yellow LED lights up ...

Page 14: ...hnological competence centers Technological competence centers Locations Distributors For more than 50 years we have been developing producing and marketing efficient sensor solutions for industrial automation ...

Page 15: ...15 ...

Page 16: ...tronic Inc 55395 Lyon Industrial Drive US New Hudson MI 48165 Tel 1 248 486 4466 info leuzeusa com www leuzeusa com YOU HAVE QUESTIONS I M HERE TO HELP Chantel Allard TechSupport US leuze com Phone 1 248 446 2484 ...