Characteristic curve of analog output
Mounting instructions
Mounting systems are available which have to be ordered separately at Leuze electronic. Apart from this, the drilled-through
holes and threaded holes are suitable for the individual mounting of the ODSL 8, depending on the area in which it is used. When
mounting, avoid application of excessive force on the housing.
A
Area not defined
B
Linearity not defined
C
Measurement range
D
Object present
E
No object detected
F
Measurement distance
Preferred movement of the objects
Preferred mounting in connection to objects with structured surface
View through a chase
If the ODSL 8 has to be installed behind a cover, the chase has to
have at least the size of the optical glass cover. Otherwise, a correct
measurement is not possible or can not be guaranteed.
Alignment to measurement objects with reflecting surfaces
If the measurement object to be detected has a reflecting surface, a measurement
may not be possible depending on the angle in which the light is reflected by the
measurement object's surface. Adjust the angle between the sensor and the mea-
surement object such that the sensor can reliably detect the measurement object.