Description ODSL 30
36
ODSL 30
Leuze electronic
3.7.2
Configuration / menu structure ODSL 30/24… (3 switching outputs)
Level 1
Level 2
Level 3
Level 4
Explanation / Notes
Default
Applic. Param.
Tmeas Bgnd Rem.
100ms 150m 6-90%
Tmeas Bgnd Rem.
100ms 150m 6-90%
Measurement time / unique-
ness range / object reflectivity
X
Note
The functions under
Applic. Param.
are not available until the
Advanced Menu
is activated
Tmeas Bgnd Rem.
80ms 39m 6-90%
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
70ms 9.8m 6-90%
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
50ms 150m 50-90%
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
40ms 39m 50-90%
Measurement time / unique-
ness range / object reflectivity
Tmeas Bgnd Rem.
30ms 9.8m 50-90%
Measurement time / unique-
ness range / object reflectivity
Disp. Resolution
1mm
Disp. Resolution
1mm
Display resolution 1mm
X
Disp. Resolution
0.1mm
Display resolution 0.1mm
Offset/Preset
Offset Direction
... positive
Offset Direction
... positive
Offset sign positive
X
Offset Direction
... negative
Offset sign negative
Offsetvalue [mm]
Value:
000000
Offsetvalue [mm]
act Val.
000000
Offset value, entry in mm
0
Presetvalue [mm]
Value:
000000
Presetvalue [mm]
act Val.
000000
Preset value, entry in mm
0
Preset Calculate
... inactive
Preset Calculate
... active
Trigger of the preset function
Return
Return to level 1
Input Menu
Inp. teach Q1/Q2
Teach Out Q1/Q2
Inp. teach Q1/Q2
Teach Out Q1/Q2
Teach input is activated
X
Inp. teach Q1/Q2
Input disabled
Teach input is deactivated
Input activ/ref
Referencing
Input activ/ref
Referencing
Input is referencing input
X
Input activ/ref
Acti Ref
Input is activation and refer-
encing input
Input activ/ref
Input disabled
Input activ is deactivated
Inp. teach Q3
Teach output Q3
Inp. teach Q3
Teach Output Q3
Teach input is activated
X
Inp. teach Q3
Input disabled
Teach input is deactivated
Input Polarity
active HIGH +24V
Input Polarity
active HIGH +24V
All inputs are active high
X
Input Polarity
active LOW
0V
All inputs are active low
Return
Return to level 1