Description ODSL 30
Leuze electronic
ODSL 30
31
TNT
35/7-2
4
V
3.6.2
Switching on
After power-on and error-free initialization of the device, the green LED
PON
lights up
continuously, the ODSL 30 is measurement mode. The display lighting remains switched
off.
In measurement mode, the LC display shows the current measurement value in millimetres.
If no object is detected or if the signal is too weak, the notice
NO SIGNAL
appears on the
display.
Notice
After an operating time of 30 min., the device has reached the operating temperature re-
quired for an optimal measurement and should be referenced then.
3.6.3
Adjustment of the display contrast
While switching the device on, press both arrow keys of the ODSL 30 simultaneously.
After releasing the keys, you can decrease or increase the contrast of the LC display with
the arrow keys (value range 0 … 255). By pressing ENTER, the adjusted contrast value is
applied and you get to the configuration menu of the ODSL 30.
3.6.4
Reset to factory settings
By pressing ENTER while switching the device on, you can reset the configuration of the
ODSL 30 to the factory settings.
A safety prompt appears.
By pressing ENTER again, all parameters are reset to factory settings. All settings made
previously are permanently lost. By pressing an arrow key, the ODSL 30 returns to measure-
ment operation without resetting the parameters.
Leuze electronic
Dist. [mm]
10687
contrast: 160
Default Setting?
Press
for OK