background image

Leuze electronic GmbH + Co. KG

Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730

IT 4820 - 03

www.leuze.de

Leuze 

electronic

Switching off the computer

Information on switching off and shutting down the connected computer - which must always be performed before connecting 
peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.

Connecting the IT 4820

Shown in the figure to the right are the locations for installing the cable on 
the base station. The individual installation steps are described in the fol-
lowing.

1.

To secure the interface cable to the scanner, proceed as follows: 
plug the RJ 41 connector into the socket on the bottom of the base sta-
tion until the cable clicks into place.

2.

Connect the interface cable to the appropriate connection socket on the 
computer.

3.

You may need a power supply unit for voltage supply if you would like to 
charge the hand-held scanner at the base station or if you use an 
RS 232 interface. Use the pin assignments (see "Electrical connection" 
on page 1) to select the appropriate cable for your application.

4.

Connect the power supply unit to the power socket.

5.

Use the code for the respective application to configure the hand-held 
scanner, see chapter "Configuration".

6.

Check the operational readiness of the scanner by pointing the scanning 
surface towards a flat surface and pulling the trigger. A green target line 
as well as the red illumination should now be visible. Now scan a sample label. 
The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the 
computer.

Configuration

The hand-held scanner can always be configured using bar codes. To do this, the barcode must first be selected on the package 
insert and then the trigger actuated in order to read the code. The configuration is then immediately accepted and executed. 

Several of the most important configurations are listed in the following.

A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the 

VisualMenu

 PC 

program. You can download and install this program from our homepage at 

www.leuze.de. 

The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so 
that it can be reused at a later time.

Further information on this can be found in the User's Guide for the IT 4820.

The standard applications are described and summarised below. 

Notice!

 

Additional information on the device and short instructions can be found on the Internet at www.leuze.de.

Resetting the IT 4820 to factory settings

To reset all parameters to factory settings, scan the adjacent 
barcode. 

Attention!

 

All settings are lost!!!

Return the IT 4820 to the base station to apply the settings. This procedure is concluded with audible confirmation signals.

You may then continue making settings or operation of the device.

Connection for
power supply unit

Connection for
interface cable

IT 4820

2D-code hand-held scanner with Bluetooth data transmission

Summary of Contents for IT 4820

Page 1: ...ies z TTL RS 232 cable PIN 9 IT 4xxx Part No 501 04586 z PS 2 cable for IT 4xxx Part No 501 03409 z USB cable for IT 4xxx Part No 501 03404 z Power supply unit for IT 4x2x Part No 501 03989 Dimensione...

Page 2: ...0 C Relative air humidity 0 95 non condensing 0 95 non condensing Protection class IP 41 IP 41 IT 4820 SR Module or cell from to Bar codes 8 3mil 0 21mm 89mm 191mm UPC bar code 13mil 0 33mm 53mm 333mm...

Page 3: ...red illumination should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the label has been read if necessary the data are now passed on to the computer Conf...

Page 4: ...lues 022 084 013 To cancel read readiness send a deactivation The command for deactivation is SYN U CR ASCII decimal values 022 085 013 Following a successful read operation the IT 4820 deactivates it...

Page 5: ...e other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacent barcode The IT 4820 is set to the following transmission parameters RS 232 transmission with 115 200 baud 8 data bits...

Page 6: ...2 white TXD 1 blue GND 4 red VCC black GND bare shield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 41 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect t...

Page 7: ...black GND bare shield PE 21 Procedure 1 Connect cable KB 021 Z to the MA 21 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power...

Page 8: ...4820 XX 0C1C 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 409 PS 2 cable Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the ST...

Page 9: ...currently activated program Thus the data can be processed further in all standard programs required parts 1x IT 4820 XX 0C1C 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020...

Page 10: ...equired parts 1x IT 4820 XX 0C1C 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedure 1 Connect the cable for the ST 2020 base station to a free...

Reviews: