Electrical connection
Leuze electronic
IPS 208i
32
Switching input/output
The sensor is provided with eight freely programmable switching inputs/outputs (SWI1, SWI3, SWI4,
SWO2, SWO5 … SWO8).
NOTICE
The function as switching input or switching output is set via the webConfig configuration tool
(
CONFIGURATION > DEVICE > Switching inputs/outputs
, see chapter 9 "Commissioning –
Leuze electronic webConfig tool").
The eight switching inputs/outputs are configured by default as follows:
• SWI1
Switching input: Trigger (default)
• SWO2
Switching output: device ready (default)
• SWI3
Switching input: Program selection 0
• SWI4
Switching input: Program selection 1
• SWO5
Switching output –X position
• SWO6
Switching X position
• SWO7
Switching output –Y position
• SWO8
Switching Y position
Function as switching input
18-
30 V
D
C
max. 8 mA
SWI (Pin 3/11/12)
VIN (Pin 1)
GNDIN (Pin 2)
2
1
1
Switching input
2
Switching input to controller
Fig. 7.3:
Switching input SWI1, SWI3 and SWI4 connection
NOTICE
Maximum input current!
Ä