Commissioning
Leuze electronic
DB 112 B
9
TNT
35/7-2
4
V
7
Commissioning
Notice!
If the indicators flash during the initial commissioning, a calibration must first be performed
on a single sheet.
First apply operating voltage. An
alignment mode
is available for commissioning. This can
be used to check the alignment of the transmitter and receiver.
Alignment mode
Notice!
After exiting alignment mode, it is
absolutely necessary to perform a calibration
.
Press the
TEACH IN
button
for > 5s and < 10s
LEDs
and
flash synchronously at 3Hz
LED
green
:
Alignment
OK
Exit:
press the
TEACH IN
button < 5s
LED
yellow
:
Alignment
critical
Align transmitter and receiver until
LED
is
green.
Only then is it possible to exit align-
ment mode!
Extraordinary exiting of alignment
mode is possible only by means of
Power OFF!
LED
red
:
Alignment
bad
Align transmitter and receiver until
LED
is
green.
Only then is it possible to exit align-
ment mode!
Extraordinary exiting of alignment
mode is possible only by means of
Power OFF!