Specifications

6

DB 112 B

Leuze electronic

4

Specifications

Technical data for sensor DB 112 UP

Technical data for analysis amplifier VDB 112 B/…

Sensor data 

Operating range 

15 … 30mm

Converter frequency 

300kHz 

±

5%

Ultrasonic lobe 

approx. 12°

Mechanical data 

Housing nickel-faced 

brass

Weight 30g
Connection type 

1.5/2.5m cable with M8 connector, 
3-pin, bending radius r > 25mm

Timing

Switching frequency 

200Hz

Input pulse 

min. 5ms

Delay before start-up

300ms

Electrical data

Operating voltage U

B

1)

1)

For UL applications: only for use in "Class 2" circuits according to NEC.

18 … 30VDC (incl. residual ripple) 

Residual ripple

15% of U

B

Open-circuit current

75mA

Switching output

2 push-pull switching outputs 

2)

2)

Function:

…/…P = active high (+24V); inactive low (0V),
…/…N = active low (0V); inactive high (+24V).

The push-pull switching outputs must not be connected in parallel

Function

single sheet detected, or 

≥ 

1 sheet

double sheet detected, or 

≥ 

2 sheets

Signal voltage high/low

(U

B

-   2V)  / 

2V

Output current

max. 100mA per output

Teach input

R

in

= 10k

Ω

TEACH-IN active/not active 

3)

3)

Setting the Teach IN input disables the TEACH IN button (see page 10)

…/…P (PNP): 

10V /

2V or not connected

…/…N (NPN): 

2V /

10V or not connected

TEACH IN duration

max. 100ms

TEACH IN delay 

4)

4)

Only applies for automatic calibration during sheet movement (automatic teach)

approx. 300ms 

Indicators

LED green A 

double sheet testing unit ready

LED A yellow

teach-in process

LED A red flashing

error (see chapter 9)

LED yellow B

single sheet detected

LED red C

double sheet detected

Mechanical data 

Housing 

aluminium, black powder-coated

Weight 400g
Connection type 

M12 connector, 5-pin

Environmental data

Ambient temp. (operation/storage) 

0°C … +50°C / -40°C … +70°C 

Protective circuit 

5)

5)

1=transient protection, 2=polarity reversal protection, 3=short circuit protection

1,2,3 

VDE safety class

III 

Protection class 

IP 65

Standards applied

EN 60947-5-2

Certifications

UL 508, C22.2 No.14-13 

1)

 

6)

6)

These proximity switches shall be used with UL Listed Cable assemblies rated 30V,
0.5A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)

Summary of Contents for DB 112 B

Page 1: ...DB 112 B Double Sheet Testing Unit T E C H N I C A L D E S C R I P T I O N en 03 2014 06 50126540 We reserve the right to make technical changes...

Page 2: ...Leuze electronic DB 112 B 2014 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze de...

Page 3: ...Areas of application 3 2 4 Organisational measures 3 3 Device overview 4 4 Specifications 6 5 Mounting the transmitter and receiver 7 6 Electrical connection 8 7 Commissioning 9 8 Operation inputs and...

Page 4: ...indicates text passages containing important information 1 2 Declaration of conformity The DB 112 B double sheet testing unit sensor system has been developed and manufac tured in adherence with the...

Page 5: ...be guaranteed if the device is operated in a manner not corresponding to its intended use Access to or changes on the device except where expressly described in this manual are not authorised 2 3 Area...

Page 6: ...ders The device functions as a presence monitor by constantly applying a signal at the single sheet output when an object is located between the sensors It functions as a double sheet testing unit by...

Page 7: ...1 5m DB 112 UP 1 20 1500 501 08999 Sensor pair M12 x 21mm cable length 2 5m DB 112 UP 1 20 2500 501 09000 Amplifier positive logic VDB 112 B 6P 501 07002 Designation Model Part No Cable 5m PVC 5 pin w...

Page 8: ...igh low UB 2V 2V Output current max 100mA per output Teach input Rin 10k TEACH IN active not active 3 3 Setting the Teach IN input disables the TEACH IN button see page 10 P PNP 10V 2V or not connecte...

Page 9: ...and can be max 30mm Ensure that alignment is exact 1 If the alignment does not run along the axis the working range is reduced Notice When aligning the transmitter and receiver take care to ensure the...

Page 10: ...nect the transmitter and receiver at the appropriate M8 connectors of the VDB 112 B analysis amplifier Connect the analysis amplifier acc to connection diagram figure 6 1 Figure 6 1 Connection diagram...

Page 11: ...it is absolutely necessary to perform a calibration Press the TEACH IN button for 5s and 10s LEDs and flash synchronously at 3Hz LED green Alignment OK Exit press the TEACH IN button 5s LED yellow Ali...

Page 12: ...remains stored until the next calibra tion process If the calibration process was not successful LED flashes red and LED illuminates red The double sheet output is activated Notice Causes of unsuccess...

Page 13: ...Hz 1 LED green Manual teach standard mode To select and exit press the TEACH IN button 3s LED yellow To advance to next press the TEACH IN button 3s 2 LED red Automatic teach on the first sheet To sel...

Page 14: ...tputs The single sheet output pin 2 is activated as long as one or more sheets are located in the measurement field The double sheet output pin 4 is activated as long as two or more sheets are located...

Page 15: ...ibrate on single sheet red flashing 6Hz red flashing 6Hz Amplifier detects insufficient input sig nal when device switched on Sheet between the sensors or sensors not connected Remove sheet and acknow...

Page 16: ...p directly on the PCB may be bridged for 5s Afterwards alignment can be carried out as described under Alignment mode in chapter 7 The device LEDs indicate the following error states In the case of VD...

Page 17: ...red with manual teach operating mode The calibration on the material to be detected is performed using pin 5 on the M12 connector Notice To enter alignment mode the 2 pin pin strip directly on the PCB...

Reviews: