Configuration / device parameters
Leuze electronic
BPS 8
83
TNT
35/7-2
4
V
Parameters
The events of the switch-on function and switch-off function are both linked to one another
with a logical OR.
Parameter
Description
Value range
Default
Unit
CR
Digital
I/O mode
Defines whether the switching
input and output are activated
via the MA 8-01/MA 8-02 or
whether only the switching input
or only the switching output is
activated.
0: Not
released
1:
BPS 8 with MA 8-01/
MA 8-02 (switching
input + switching
output)
2: Switching
input
3: Switching
output
1
–
–
Bias level /
inverted
The parameter defines the bias
level of the switching output.
0: LOW (0V)
1: HIGH (+Ub)
0
–
–
Pulse dura-
tion in [ms]
The parameter defines the
switch-on time period for the
switching output. If the value is
0, the signal is static.
0 ... 1300
400
ms
–
Switch-on
function
[EF]
The parameter specifies the
events which set the switching
output:
Each
0: Not active
1: Active
–
- outside measurement range
0
Position
detection
,
- within measurement range
0
Position
detection
,
- erroneous measurement
1
Position
detection
- successful measurement
0
Position
detection
Switch-off
function
[AF]
The parameter specifies the
events which reset the switching
output:
Each
0: Not active
1: Active
–
–
- outside measurement range
0
Position
detection
,
- within measurement range
0
Position
detection
,
- erroneous measurement
0
Position
detection
- successful measurement
1
Position
detection
a
b
c
d
i
j
i
j
e
i
j
i
j