Mounting and installation
Leuze electronic
BPS 8
32
TNT
35/7-2
4
V
NOTE
BCB application
Make certain that the BCB is located in the scanning beam of the BPS over the entire
traversing path.
The BPS can determine the position on BCBs with arbitrary orientation.
Bar code tapes with different value ranges may not directly follow one another.
In the case of different value ranges, a gap of at least 1 m must be maintained between
the last position bar code value of the preceding BCB and the first position bar code
value of the subsequent BCB (see Chapter 5.2).
For MVS control bar codes (see Chapter 5.2), the minimum distance of 1 m between
the printed value of the last position bar code before the control bar code and the
printed value of the first position bar code after the control bar code must be main-
tained (BCB8 printed values in cm).
In the case of bar code tapes with different value ranges, both BCBs must be
BCB8-type in a 30 mm grid (see Chapter 5.1).
When using the position bar code with the value ’000000’, negative values are output
for position measurements to the left of the label.