18
BCL 558
i
Leuze electronic
Configuration of the participant using the EDS file
From software version 20.00 and up, proceed as follows in the
RSLogix 5000
configuration
tool to create the BCL 558
i
as an EtherNet/IP participant in your system:
• First, load the EDS file for the device via EDS wizard into the PLC database.
Notice!
You can find the EDS file at:
.
• After it has downloaded, select the device from the device list.
• Open the input dialog for setting the address and additional parameters by
double-clicking on the device symbol and make the desired entries here.
• Finally, transmit the values to the control via download.
3.4.4
Transferring the data to the control (RSLogix 5000 specific)
• Activate online mode
• Select the Ethernet communication port
• Select the processor onto which the project is to be transferred
• Set the control to PROG
• Start the download
• Set the control to RUN
3.5
Further settings
After the basic configuration of the operating mode and the communication parameters, you
need to carry out further settings:
• Decoding and processing the read data
Define at least one code type with the desired settings.
• Via webConfig:
Configuration -> Decoder
• Control of the decoding
Configure the connected switching inputs according to your requirements. To do
this, first set the I/O mode to Input and then configure the switching behavior:
• Via webConfig:
Configuration -> Device -> Switching inputs/outputs
• Control of the switching outputs
Configure the connected switching outputs according to your requirements. To do
this, first set the I/O mode to Output and then configure the switching behavior:
• Via webConfig:
Configuration -> Device -> Switching inputs/outputs