Technical Description BCL 90
Leuze electronic
8.6
Oscillating-Mirror Functions
1. Operating mode "oscillating at predefined amplitude"
The oscillating mirror deflects the scan line up to a maximum deflection width of ±40 CW (equivalent
to ±20°). Figure 8.3 shows an overview of reading from the top.
Figure 8.3: Oscillating mirror operating mode "oscillating at predefined amplitude"
2. Operating mode "oscillating at variable amplitude"
The deflection is randomly adjustable for each of the max. 8 distance configurations/focus positions
separately. Limiting the oscillation range ensures that the scan line sweeps only relevant areas in
which there are bar codes in the short time available in rapid applications. At the same time, this allows
the scan line density on the object to remain nearly constant. Figure 8.4 shows the application of a
reading from the top.
0
0
Oscillation frequency
constant
Scan line density depending on object height