Display and control panel AMS 384i
37
AMS 384
i
Leuze electronic
LSR
Warning - laser prefailure message:
Laser diode old, device still functional, exchange or have repaired.
TMP
Warning - temperature monitoring:
Permissible internal device temperature exceeded / not met.
PLB
Plausibility error:
Implausible measurement value. Possible causes: light beam interruption, outside
of measurement range, permissible internal device temperature considerably
exceeded or traverse rate >10m/s.
Depending on the configuration, either zero or the last valid measurement value is
output at the interfaces.
ATT
Warning received signal:
Laser outlet window or reflector soiled or fogged by rain, water vapor or fog. Clean
or dry surfaces.
ERR
Internal hardware error:
The device must be sent in for inspection.
Bar graph
Indicates the
strength of the received laser light
.
The center bar represents the
ATT
warning threshold. The distance value remains
valid and is output at the interfaces.
If no bar graph is available, the
PLB
status information appears at the same time.
The measurement value has thus been assessed as being implausible. Depending
on the configuration, either zero or the last valid measurement value is output at the
interfaces.
Interface info
The abbreviation "IBS" stands for the Interbus interface.
Position value
The measured position value is displayed in the configured unit of measurement.
+87.000 m
With the
metric
setting, the measurement value is always displayed in meters
with
three decimal places
.
+87.0 in
With the
inch
setting, the measurement value is always displayed in inches
with
one decimal place
.
Interbus interface
Position value
IO1
LSR
PLB
IBS
IO2 TMP
ATT
ERR
+ 87.000 m