background image

Operating Instructions

7

00949U

WIRING DIAGRAM

BLACK

DC
OUTPUT

TRANSFORMER

+

-

SCR

WHITE

SHUNT RESISTOR

BLACK

RED

R

E

D

ORANGE

O

R

A

N

G

E

W

H

IT

E

9
7
6
5
4
3
2
1

BLUE

BLACK

BLUE

YELLOW

BROWN

BROWN

B

R

O

W

N

BR

OW

N

ELECTRONIC

TIMER

Y

E

L

L

O

W

WHITE

4

5

6

7

RED

WHT

WHT

RED

SCR

AMMETER

BLK

GRN

WHT

AC

INPUT

PLUG

BLUE

WHITE

BLUE

P

P

1

3

2

POWER

SWITCH

L2115S19

PARTS LIST

MODEL 12610 TYPE 24EL8

PART NO.        QTY.            DESCRIPTION                                                            

14432S

1

CASE ASSEMBLY

12600S

1

TRANSFORMER ASSEMBLY

12245S

1

ELECTRONIC TIMER ASSEMBLY

13811S

1

AMMETER, 10 AMP

14308S

1

CONTROL CABLE ASSEMBLY

15184S

1

SWITCH, SLIDE, SPST, 1225 VAC, 6 AMP

14341S

1

THYRISTOR ASSEMBLY

04275S

2

BUSHING, INSULATOR, 6N3-4, FOR CORDSETS

14444S

1

CORDSET, AC, 18/3, 102", MD PL

14421S

1

CORDSET, DC, 108", BLACK & RED POWERPOLE

14422S

1

CORDSET, DC, 108", YELLOW & WHITE POWERPOLE

16626S

1

CORDSET, DC, 108", WHITE & BLACK POWERPOLE

16671S

1

CORDSET, DC, 108", W/ ALLIGATOR CLIPS

16672S

1

CORDSET, DC, 108", W/ HIRSCHMANN PLUG

16612S

1

CORDSET, DC, 108", W/ CANNON PLUG

16221S

1

CORDSET, DC, 108", W/ REVERSE CANNON PLUG

17219S

1

CORDSET, DC, 108", W/ SB50 GRAY PLUG

20838S

1

CORDSET, DC, 108", W/ SB50 RED PLUG

17219S

1

CORDSET, DC, 108", W/ SB175 GRAY PLUG

14419S

1

CORDSET, DC, 108", NO PLUG

09942S

1

PLUG ASSEMBLY, FOR SB50 GRAY PLUG

02957S

1

PLUG ASSEMBLY, FOR SB175 GRAY PLUG

21667S

1

CORDSET, DC, 108", W/ 30 AMP POWERPOLE

18034S

1

CORDSET, DC, 108", W/ 15 AMP BEAU

23014S

1

CORDSET, DC, 82", W/ CANNON PLUG

19974S

1

CORDSET, DC, 108", W/ CANNON PLUG, AUSTRALIA

Summary of Contents for 12610

Page 1: ...s Charger output characteristics are adjustable to charge gel cell and sealed or conventional replaceable liquid electrolyte deep cycle lead acid batteries Different charge characteristics are selected by a switch on the front of the charger Patented electronic circuit monitors battery state of charge and automatically turns charger off when the batteries reach full charge Line voltage compensatio...

Page 2: ...both batteries and charger The convection cooled design requires an unobstructed flow of cooling air for proper operation Keep all charger ventilation openings at least two inches 2 5 08cm away from walls and other objects Do not allow clothing blankets or other material to cover charger DO NOT place under bed WARNING CHARGERS CAN IGNITE FLAMMABLE MATERIALS AND VAPORS DO NOT USE NEAR FUELS GRAIN D...

Page 3: ...Power switch is in the OFF position and the power supply cord is disconnected CAUTION MAKE SURE THE BATTERY PACK IS A 24 VOLT 12 CELL SERIES CONNECTED 28 85 AMP HOUR 20 HR RATE RECHARGEABLE DEEP CYCLE BATTERY SYSTEM THE GEL CELL AND SEALED DEEP CYCLE BATTERY SETTING CHARGES TO A MAXIMUM ON CHARGE VOLTAGE OF 2 35 VOLTS PER CELL THE REPLACEABLE ELECTROLYTE DEEP CYCLE BATTERY SETTING HAS AN ON CHARGE...

Page 4: ... still determine when the batteries are as charged as they are capable of being and turn off When the batteries will no longer perform as desired they should be replaced Charger is equipped with a temperature sensor which automatically turns the charger off if it overheats Should charger turn off before the batteries are fully charged check to be sure all ventilation openings are free from obstruc...

Page 5: ...ey are fully charged do not overfill Old batteries require more frequent additions of water than new batteries 5 Keep tops of batteries clean and dry to prevent excessive self discharge Keep the battery terminals reasonably tight PERSONAL PRECAUTIONS 1 Someone should be within the range of your voice or close enough to come to your aid when you work near a lead acid battery 2 Have plenty of fresh ...

Page 6: ... Charge the battery no less frequently than once every three 3 days when the equipment is lightly utilized Once sulfation is allowed to take place it may be partially reduced by returning temporarily to daily charging 3 The decrease in equipment range where the chair loses power earlier and earlier in the day indicates one of the following a The electrolyte level in conventional liquid electrolyte...

Page 7: ... ASSEMBLY 04275S 2 BUSHING INSULATOR 6N3 4 FOR CORDSETS 14444S 1 CORDSET AC 18 3 102 MD PL 14421S 1 CORDSET DC 108 BLACK RED POWERPOLE 14422S 1 CORDSET DC 108 YELLOW WHITE POWERPOLE 16626S 1 CORDSET DC 108 WHITE BLACK POWERPOLE 16671S 1 CORDSET DC 108 W ALLIGATOR CLIPS 16672S 1 CORDSET DC 108 W HIRSCHMANN PLUG 16612S 1 CORDSET DC 108 W CANNON PLUG 16221S 1 CORDSET DC 108 W REVERSE CANNON PLUG 1721...

Page 8: ...ory to the owner will be paid for by the owner All warranty work accomplished at the Lester factory will be completed with a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Lester Warranty on parts not manufactured by Lester which include but are not limited to ti...

Reviews: