Wood frame for the
regular ceiling
support
DRAWING 4
Don-Bar
regular
ceiling support
Fireplace hood to
be bolted to the
ceiling support
17"
(43
0 m
m
)
17
" (
43
0 m
m)
Lo
ng
b
olt
h
ole
s
at
18"
c/c
(4
60 m
m
)
ce
ilin
g s
up
po
rt
20
" x
20
"
(50
8 m
m x
50
8 m
m)
3.5 Minimum clearances from combustible
materials:
Make sure the wood basket (see
drawings 2 and 3) is at least 12" (305 mm) from
any combustible material, including furniture,
drapes and other flammable objects. Note that
Type X fire-resistant gypsum board (Firecode) is
c o n s i d e r e d c o m b u s t i b l e f o r f i r e p l a c e s
installations and as such requires the minimum
12" (305 mm) clearance.
3.6 Exterior doors and windows:
As much as
possible, avoid installing the fireplace too close to
an outside door or window because air turbulence
and drafts disrupt the chimney draft.
4.1 Choosing the ceiling support:
If you have a
horizontal ceiling, use the regular Don-Bar
ceiling support. For a sloped ceiling, use the
Don-Bar cathedral ceiling support.
5.1 Wood frame:
Build a ceiling wood frame of
17" x 17" I.D. (432 mm x 432 mm) to anchor the
ceiling support. The ceiling support long bolts
are spaced at 18" c/c (457 mm). Level the frame
so that the suspended hood will be plumb.
Note
that these wood frame dimensions are required
to fix the ceiling support. Elsewhere, the
chimney may require smaller clearances. See
t h e r e q u i r e m e n t s o f t h e c h i m n e y ' s
manufacturer for more details.
5.2 Ceiling support fastening:
Secure the
regular Don-Bar ceiling support to the wood
frame with 4 long bolts at least 3" (75 mm) long
by 3/8" (10 mm) diameter.
5.3 Chimney:
Start the chimney installation by
slipping the first chimney section into the ceiling
support. Be sure the chimney fits well into the
ceiling support before proceeding with other
chimney sections.
4. Installation
5. Regular ceiling support
installation
DRAWING 5
Chimney start on the regular
ceiling support
Factory-Built
Chimney
10" I.D.
(250 mm)
Fireplace Hood to
be bolted to the
Ceiling Support
Don-Bar
Regular Ceiling
Support
Fixing Bolt
Radiation
Shield
Long Bolt
17" (430 mm) required for long bolts
2" (50 mm)
Minimum
Mandatory Air
Space
2" (50 mm)
Minimum
Mandatory Air
Space
Page 8
REV. 2013-02
Summary of Contents for 9000
Page 16: ...Page 16 REV 2013 02 ...
Page 22: ...Page 22 REV 2013 02 ...