14. BBQ grill installation
15. Gas burner (optional)
14.1 BBQ brackets installation:
Fix one of the
three BBQ grill brackets on each side of the
fireplace wood basket with the supplied wing nuts
and bolts. Next, install the support rod and the
BBQ grill at the desired level.
15.5 Connection of the outside air intake:
The
outside air intake located below the burner support
plate must be connected to a flexible insulated duct
of at least 6” diameter. The air intake’s flexible duct
must be extended to reach the outdoors and a fresh
air supply.
It should not end in an attic space,
another room, crawl space or any other confined
space; that space being vented or not.
15.1 Gas Burner (Propane or Natural Gas):
The installation requires a special table equipped
with a support plate and integrated air intake, as
well as a pedestal with an access door
(Drawing
15).
The installation must follow the instructions
of the burner manufacturer, local codes and the
present section of this manual where it is most
restrictive.
15.2 Regulations and certification:
The
installation must be done in conformity with the
standards regulating gas installations in the locality
where the fireplace will be installed. The burner and
its accessories must have the approved
certification of the authorities of the country in
question
.
15.3 Neutral pressure required:
Special care
must be taken regarding pressures and air
movements inside the area where the fireplace will
be installed. There must be no negative pressure
(vacuum) in the fireplace’s environment.
The
outside air intake supplied with the fireplace only
serves to ensure it’s correct operation in a neutral
pressured environment.
Certain conditions that are
out of our control ( Air exchangers, windows,
dryers, cooker hoods, air movements between
floors, etc.) can produce negative pressures in the
fireplace’s environment. In that case, all required
measures must be taken to rebalance pressure and
obtain neutral or, even better, a slightly positive
pressure.
15.4 CO detector:
A carbon monoxide detector
must be installed in the room where the fireplace
will be installed. Check batteries on a regular basis.
DRAWING 15
Gas burner installation
(optional)
Burner controls
hidden in the
pedestal
Special gas
pedestal with
an access door
Table
Burner
support plate
Replace the rigid gas pipe
supplied with the burner
with an approved flexible
gas pipe
Flexible gas
Gas burner
pipe
Adjustable
levelling bolts
Outside air intake
with damper to be
connected to a 4" (100 mm)
dia. insulated flexible
duct that reaches
the outdoors