3. Before beginning the installation
ceiling support requires 20-1/4” x 20-1/4” (515
mm) - see next page.
Do not connect this
fireplace to a chimney that is connected to
3.1 Choosing the best location:
Before
another heating device.
beginning the installation, make sure the spot you
have in mind for the fireplace and the chimney
3.3 Chimney minimum height:
15 feet (4600
meet the following requirements:
mm). This length is measured from the floor
where the fireplace is installed to the top of the
chimney.
3.4 Outside air intake:
Outside air needs to
circulate into the fireplace. The outside air intake
duct needs to pass under the floor that supports
the fireplace. Plan an appropriate path for this 6"
to 8" (150 to 200 mm) outside diameter duct,
including its insulated jacket.
3.2 Chimney:
Position the chimney to avoid, as
much as possible, offsets, elbows and the cutting-
out of structural elements. Allow at least 2" (50
mm) for air space between the chimney and any
combustible material including electrical cables,
and plastic plumbing pipes. Never fill this air
space with insulation. For example, if the
chimney has an outside diameter of 12" (305
mm), by adding the required 2" (50 mm) air
space,
a 16" (406 mm) free continuous path is
required to install the chimney.
Note: The
standard ceiling support requires a free vertical
space of 17” x 17” (430 mm) and the cathedral
Fireplace
DON-BAR 9000
Floor
Protection
12" min. (305 mm)
18" min. (460 mm)
See pages 17 to 21
DRAWING 2
Fireplace clearances from
combustible walls
(See also pages 17 to 21)
Wall
Floor
Protection
Fireplace Table
Wood Basket
Furniture
Wall
Fireplace clearances from walls
and combustible furniture
(See also pages 17 to 21)
DRAWING 3
Page 6
12" min.
(305 mm)
12" min.
(305 mm)
See pages 18 to 23
S
ee
p
ag
es
1
8
to
2
3)
REV. 2013-02
18" min.
(460 mm)
Beam